Laserfiche WebLink
' i i <br /> Plan Check No. B 59552 <br /> August 27, 1998 I <br /> Page 3 of 5 � <br /> � The size and location of the attic vents (those other than the eve vents) should be shown on the <br /> plans. Each attic space separated by draft stops will require its own vent system per Section <br /> 1505.3. Calculations should be provided. Note that the corrosion resistant metal mesh with <br /> openings of 'k" in dimensioii will reduce the net free venting area to 75% of the gross. <br /> Exiting <br /> �1- A note is shown on detail 5/SD-2 stating that only the third floor entry doors are to be rated for <br /> 60 minutes. This note sl�ould be removed as all doors served by the three floor sWir enclosures <br /> are required to be one-hour rated. Section 100533.5 _ <br /> Accessibility <br /> �1.' The site plan should show an wccessible route of tra��el from the public way to the accessible <br /> entrances. Section 1103.2.2 I <br /> 2t On� additional accessible parking space should be shown on the site plan as the total number of <br /> -'� parking spaces on sire exceeds one per dwelling unit. Section 1107.1.4 <br /> �-�3 The ma:eimum slope for curb cut ramps should be shown as 1:12. Section 1106.8 <br /> �4�Stair nosings should be shown rounded to a radius of '/z" (maximum). Section 1106.9.3 <br /> �5� Permanent barriers should be shown around the bottom of the open stairways to prevent entry <br /> � by persons with visual impairments into the areas of reduced headroom. Section 1106.4.2 <br /> ,f� The following comments refer to the Type A dwelling unit: <br /> a:� The tub seat should be shown on the plans. Note that the rype of seat determines the <br /> — length of the grab bars on the back wall. Section 1106.11.9.2 <br /> b� The tub should have a shower spray unit with a hose at least 60" long, that can be used as <br /> � a fixed shower head, or as a hand-held shower. Section 1106.1:.9.4 <br /> c.' The kitchen should have a counter portion measuring 30"x24" with a maximum height of <br /> 3�3" shown on the plans. The space beneath the counter should be at least 29" high. 30" <br /> wide and l9"-25" deep. Sections 1(06.2.3 & 1106.12.2 <br /> � <br />