Laserfiche WebLink
�J <br />From the list of Plan Check comments dated 3/6/2012 <br />General <br />1 A to-scale floor plan has been generated indicating type of room, doors, walls, windows, sta�rs <br />and ramps and is four�d on sheet A2 Conslruction details requested are shown on sheet A3. <br />2 New, existing and demolition areas of work are shown on the floor plar on sheet AZ along with <br />a key showing the symbolic representation for each type of work. <br />3. Details, materials, and dimensions are n�ted on the floor plan on sheet AZ, or on the elevat�ons <br />on sheet A3. <br />Occupancv <br />1. Occupancy and square foolage is shown in the Project Data section on sheet A0. <br />2 Applicable codes are referenced in the Project Data sactio� on sheet A0. <br />Construction <br />1 Extent of new construction in the bathroom is hmited to like-for-like replacement o( fixtures. <br />Notas to this effect are found on the flaor plan on sheet .42 and in the scope of work descnption <br />in the Project Data section on sheet A0. <br />Z The Van Accessible parking stali has had a� 8' width dimension added and is found on sheet <br />A1 drawings A"Enlarged Parking Space Plan". <br />3. The clear width of the exterlor accessible route has been increased to 44" on the Floor Plan on <br />sheet A2. Paved markings and the ramp are shown on the Site Plan sheet A1. <br />4. Ramp landings have bee� adjusted for the required 60" square space per the iCC on sheet A2. •, . <br />5 A note calling for a universal sign of accessibility has been added to the floor plan sheet AZ and : ; <br />detail 3/A2 has been added which shows the sign. <br />6 Threshold and Changes in Level details have been added in detail 2/A2 <br />7. • Door clearance is adequate given the swing of the door, and the 60"x60" required landing <br />and interior space around the entry door. <br />1. A note requiring that the accesible entry hardware not require �ight grasping, tight pinching, <br />or �visting per IBC seciion 10132 has been added to the Floor Plan on sheel AZ. <br />8. Handrails are shown on both sides of the ramps and stairs on the Floor Plan on sheet A2. <br />. Handrail height, profile and extensions are noted on the Floor Plan on sheet A2 <br />9. Height of the ramp is not to exceed 30" above grade. <br />10.The 60"x60° required landing at the door requires that naw stairs be added to the existing stoop <br />A note stating ,he minimum tread and maximum riser has been added to the Floor F'lan on <br />sheet A2, <br />