Laserfiche WebLink
Dclailcd drawings in accordancc with City Dcsign and Construction Standards shall bc submined to <br />the Public Works Departmcnt, showing utilitics, storm drainage, temporary construction erosion <br />control, and all required improvements in thc public right-ot way. Public Works Dcpartment <br />approval of these drawings is rco,uired prior te any permits being issued. All improvements shall bc <br />completed, approved and warranted before the final approval is granted. <br />2. Temporary erosion control mcasures for construction activity must be operational prior to <br />commencemcnt of any cicaring or carthwurk. <br />3. Any grading/fill on this site shall bc donc so as to not impact thc surrounding propertics. <br />4. City streets are to bc kcpt clear of dirt and debris at all times during consWction. Dust suppression <br />and street cleaning must occur as directed by the Public VVorks Inspcctor. <br />Public water main must be installcd �or this project in accordance with City Design and Construction <br />Standards. <br />6. A fire hydrant capable of pro��iding the requircd fire Oow must bc locatcd within 200 d�iving fcet of <br />the structurc. 7'hc Ciry Firc Marshall must approve localion of thc hydranL The hydrant must mcet <br />Ciry specific�tions. <br />A one-ycar guarantee is rcquired on lhe public improvement for an amount not Icss than 10% of thc <br />cost of construction and shal: run for one year from the datc s,f final approval. <br />R. As-builts of s!omi scwcr, sanitary sewcr, and watcr systems will be required to be submitted per City <br />Design and Conswction Standards and Speci fications for Devclopment. <br />9. The uct new one (1) PM Peak hour trip generated by this projcct yields a traffic mitigation fec of <br />$900.00, which must be paid prior to issuance of construction permit�. <br />10. Walkways must be provided from the public sidcwalk !o each building mccting ADA standards. Thc <br />unsitc crosswalk should be 8' wide. <br />1 1. Detention of storniwater runoff is rcquired in accordance with City standards. <br />12. Trcatment of stormwatcr runoff will be required if thc proiect will create and/or redevclop morc than <br />5,000 square fcet of pavcment. Anything o0ier than routinc maintenance of pavement (such as re- <br />striping and ovcrlaying) is considered redevclopmcnt of thc pavemcnl. <br />The options for slorni water trestment are: <br />a) a wetpond; <br />b) a constructed wcUand. <br />13. All stomi watee facilities shall be designcd in accordance �ti�ith Ciry standards. <br />14. Parking must be per City Zoning Codc and City Ucsign and Constructien Standards for Devclopmcnt. <br />15. This projcct must comply with thc currcnt City of Evcrctt Building Code and Sprinklcr Ordinancc. <br />�� <br />