Laserfiche WebLink
� <br />:� <br />�' 6� e plans should indicate methods of compliance with the 97 WA. State Ventilation <br />�:md Indoor Air Quality Code. <br />"7. UBC ] 105.4.1 azid l 106.1_ r::yuire two water fountains (one at standard height and <br />one at accessible height). <br />8. UDC 1106.11.10.1 requires transfer showers to be 36" by 36". Please revise. Also <br />reference elevations 02 & 63/A6.01 appear misplaced. <br />9. UBC 1106.11.10.2 requires Uansfer showers to have a 48" x 36" maneuvering spa�e <br />that extends 12" beyond the seat wall. Pleasc revise t,ype HC Unit "B1" Rm. #17. <br />Please prepare a response letter showing where each item in this letter is addressed on the <br />plan set. <br />Upon submittal of the drawings, your application will be given priority and plan review <br />will recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to <br />ensure that the proposed structure will be conshucted in compliance witl� all adopted <br />codes. <br />Sincerely, <br />� <br />Steve Miller <br />Associat� Engin.er <br />S\1jC60005-013 <br />�L <br />