Laserfiche WebLink
0 <br />PUBLIC WORKS PERMIT COMMENTS <br />4. As per Public Works approved plan dated <br />5. Connect siJe sewer per City Standard #601. <br />6. Connect side sewer per City Standard #'s 601. 602, 604. <br />7. Connect all rooftop downspouts to the side sewer. <br />� Connect rooftop downspouts to the drainage system provided for this lot. <br />� Rooftop runoff must be discharged, to a roof downspout infiltration system �er Ciry of Fverett <br />Storm Manual 3-2.6.2. Width _�, Depth 2�, Length 17'. +3 �= � <br />10. A catch basin as per Ciry Standard Plan #402 viith a gas trap per Standard Plan #410 is <br />required for the parking area. <br />11. Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan #'s 305A <br />& 306 on this proposal's frontage as directed by the Public Works Inspector (i.e. all unused <br />driveways and any broken or damaged area must be replaced). <br />12. Inst 'I a Type I concrete driveway per City of Everett Standard #307. <br />�� Pave driveway from the front property line out to the street paving. <br />14. Contact the ft/I �l �!i � i�,Zi Water District for connecting provisions for this building's <br />water and sewer services. <br />15. If a sewer pump system is to be installed, the pressure line must discharge into a private <br />manhole, then gravity flow across the public right-of-way. <br />16. The contractor must meet with the Pubiic Works Inspector to discuss potential drainage <br />routing prior to beginning the project. <br />17. A sprinkler system is required for this buildi�g in compliance with the requirements of NFDA <br />Standards 13D. <br />�-- _ i <br />�1�,�AD��Y_">l 1-Ci���IF-, e��c���.t�}"t � itil DP�V�tVA�� <br />PVICommerts <br />