Laserfiche WebLink
January 7, 2010 <br />�'UBL/C fY�R/C5 <br />I.arry Wahl <br />9013 4"' Avc W <br />Gverett WA 98204 <br />Subject: Project: <br />1ob Address: <br />Plan Chcck No <br />Dear Mr. \'Vahl: <br />Wahl <br />9U13 4`" Ave W <br />C0712-017 <br />in response to your application for a construction permit, your plans have been examined and <br />you are advised that the issuancc of a permit is bemg withhcld (or the rcasons listcd below. <br />ihesc comments address building issucs only. Additional revisions or additions may bc <br />required by other departments (such as Utilities, Planning or Firel. All references refer to the <br />(2006 Intemational Building Co�e,) (2006 [nternational Rcsidential Code,) as amended by the <br />State of Washington and/or �Vashington State Energy Code 200G �dicion, and adopted by dic <br />Ciry of Gverett, unlcss statcd otherwise. <br />[n order for the processing of your application to conti��ue, it will be necessary to provide <br />tlic Building Division R'Iill lN'0 new complete sets of d-�wings reftecting the corrections <br />requcsted. <br />�. Provide detail of:!Itemate braced wall panel (ABWP) cons[ruction at 2'-8" garage <br />wall (show minimum 2'-8" width and hold dowas on thc foundation plan). <br />�rovid� (l) foundation vent within 3'-0" of all corners; show on foundation plan. <br />�! 3 <br />�/ 4 <br />Provide detail of insulation baffle at rim loist for foundation vcnts. <br />I x 4 scab at post and be.vn is rcquireJ on Iwo opposite sides. <br />�/ 5. I=ootings shall rest on undisturbcd soil not lcss than 13" bclow thc Gnisliccl gradc; <br />show on plans. <br />v o. Show thc finished grade and thc botlom of thc siding en thc elevations. <br />v 7. Provide step(s) as needcd from lhe house lo the garage (7 �b " maximwn rise, 10" <br />minimum run, minimum 3G" widc). <br />�8. Braced wall panels are required in both the transverse and longitudinal direction <br />in each story (RG02.10.1.1 IRC). All braced wali panels (D�'VP) shall bc clearly <br />marked on the plans. Provide doublc joists under parallel 13WP. and blocking <br />w�dcr perpendicular walls. <br />�9. Provide minimum ]00 cfin exhaust fan in the kitcl�en, minimum SC cfm fan in the <br />bathrooms and laundry room. <br />1<nllimn'Milmu'CMIt 011141U P A�t Nl <br />ENGINEERING / PUBLIC SERVICES DIVISION • 3200 Cedar Slreet • Everetl, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />