Laserfiche WebLink
PUBLIC WORKS PERMIT COMMENTS <br />4. Connect side sewer per City Standard #601. <br />� Connect side sewer per City Standard #'s 601, 602, 604. <br />6. Connect all rooftop downspouts to the side sewer. <br />7� Connect rooftop downspouls to the drainage system provided for this lot. <br />8. Rooftop runoff must be discharged to a roof downspout infiltration system per Cily of Everelt Storm <br />Manual 3-2.6.2. The approximate size trench is 3.5' wide, 2' deep and 25' long. See attachment for <br />more details. <br />9. The contractor must meet wilh the Public Works Inspeclor lo discuss potential drainage routing prior to <br />beginning the project. Call Rand Allen at 425-339-7403 // Call Cliff Lindman at 425-339-7404. <br />10. <br />13. <br />Install erosion conlrol measures as determined by the Public Works inspector, such as silt (ence, straw <br />bales, swales, or erosion blankels. <br />Install erosion control measures per City of Everett Standards for small parcels <br />Remove erosion control measures upon completion of the project prior to final approval of Qie pennit. <br />All excavated malerial from foundalion, sidewalk and driveways shall be hauled lo an approved, <br />permitted site. No wasting of material is allowed on this building lot. <br />� No dirt, mud, rocks or debris to be tracked onto roadway. <br />�,�- <br />�5. >� No building materials to be slacked on sidewalklroadway acd sidewalk/roadway to be kept clean and <br />— open for pedestrian travel. <br />16. Adjust waler meter box 1" above sidewalk grade. <br />17. Remove and replace curb, gutler and sidewalk as per City of Everelt Standard Plan #'s 305A 3 306 on <br />this proposal's frontage as directed by lhe Public Works Inspector (i.e. all unused driveways and any <br />broken or damaged area must be replaced). <br />� <br />19. <br />Install a Type 1 concrete driveway per City of Everett Standard #307. <br />Pave driveway from lhe front property line out to the slreet paving. <br />20. Pave to existing paving in alley. <br />r�, <br />,; 2�. J Contact the /%Ci/�/L7�C�' V�later Dislrict for connecting provisions for lhis building' <br />� �-- sewer services. <br />22. A catch basin as per City Slandard Plan #402 with a gas trap per Standard Plan #410 is required for the <br />parking area. <br />23. If a sewer pump system is lo be installed, the pressure line must discharge into a private manhole, then <br />gravity flow across lhe public right-of-way. <br />24. A sprinkler system is required for this building in cor,ipliance with Uie requirements of NFPA Standards <br />13 D. <br />,i <br />P1VCommen;slRev�ed6E111 - � <br />