Table 33A max. load for a esit = 30 there.orc 2 exits <br />required. - 5 exits provided (exits are door��ays to <br />exterior (public May)) <br />kOR�SAOP/Gd^n�GE <br />Occupant load <br />- Maintenance workshop - 1 for 100 sq, ft. <br />(1280 sq. ft.) = 12 <br />- Storage/Stock Rooms - 1 for 300 sq, £t. <br />(300 sq, fL.) = 1 <br />- hlezzani.ne Storage - 1 for 300 sq. ft. <br />(700 sq. ft.) - � <br />TOTAL B�G OCCUPANCY = 15 <br />Table 33A max. l�ad�for 1 exit = 30 therefore 1 exit <br />' required. Section'�320 overrules - 2 exits to be provided. <br />/ ------- <br />A ruling is required regarding corridors - <br />- 3305 (al and (g) define and require corridors to <br />be ��,our rated. This would mean taking <br />partitia�s to underside of roof structure (then <br />fire da�apers would be required on ducts passing <br />throu�h) or the installation of. a fi.re rated <br />ceiling. <br />- 1705 (b) excepts the above if occupant load served <br />Uy eorridor is less than 30. <br />- s in fact most unlikely that the Conierence <br />Ro m would ever accommodate 23 as calculated by <br />a e . <br />-�Also, can the fully glazed t+all between Reception � <br />& Lobby be excepted from corridor wall (rated or <br />c1� unrated) classification - the Reception Gould in <br />fact be part of [he Lobby be the exception to 3305 <br />(a) <br />- Also, the doublc doors to the laboratory should be <br />� glass. <br />;�,/ <br />