Laserfiche WebLink
, � <br /> OOMPLIANCE ' ' • • / � � . , <br /> RE�UIRED � <br /> INSPECTION �MpORTANT:Su I Iniortnation and check approprlate clrcles In the shaded boxes. <br /> , AP�ROVED DlsreAard topicsth t don't descrlbe your bullding or equipment.DO NCT place checks in <br /> the two leR columns. <br /> . , . , <br /> _ _ _ <br /> � O n Exhaust ventlletlon shall be provided(or each dwellinp unit as follows(VIA�S.303): <br /> . .., :.,,. ,,: ,.,.,... ,. ..,,.. <br /> . ,,,.. <br /> Locatlon Mlnlmum at.25 w.g. M(r✓model �Fan label CFM(1 W.G.) <br /> � KRchen fan 100 CFM �, - <br /> ,' Bathroom tan(_.'L_) 50 CFM � <br /> Bathroom fan(_) 50 CFM <br /> Bathroum fan(__J 50 CFM <br /> Laundry(an 50 CFM <br /> . (� 00 CFM (1-2 bedrms) <br /> �e Whole house tan' �n 80 CFM (3 bedrms) <br /> (choose oneJ W( <br /> Q 100 CFM (4 bedrms) <br /> Whole hcuse tan: Localion�i'C�{�. Sone �atfn _� <br /> ceiling) 8 '(s 1.5NatticfancbsefYhan 4'Io <br /> � VJhoie house!an is iisted9abied'Yor Continuous use'. <br /> Whole house fan wiring for control routad to central iocation {dehum�d�staf or.lyJ. <br /> O O �9 �Whcie houso fan also sorves as a kltchen or bath spot lan. � Yes �,No <br /> I il a spot}an !s dQsignated as a whole� house lan,the capacKy sli��l be the larger C("M requireme�t: <br /> � 0 � Whole houso ian shall Nm m�tfnuouslyi KitChen(25QFM); Bath&laund.`(20CFM) �Yes �No ' <br /> O O Qi Integrated forced•al�t��mace ventllatlon(IA�Code,S.303.1.2{b)) shall be:synchronized with a : <br /> whole housc t�n to�upply tresh air tG1he dwelling: ` (�Yes �'} No <br /> O ii yes, a G'outside air inlot duct w/motorized damper shaU.run from itie twilding ext�rior to io <br /> the furnace retum plenum ancl limft the ventiltion rate to betweeo:35-:56 Air CtianyeslHour. <br /> O ModHications io the above integrated torced airsystem may requlre pertotmance t�s�ipg, In a <br /> mannor a�eptable!o the Buiioing Otficial, to tlemonstrate .35-.S air chhngesper hour. <br /> O O Q Mechanlcal ventllation tan ducts shall bs 2 4"and properfy sized (VIAQ,Table 3•3). <br /> O O QFresh alr shall be provided for eacti d�reiling unit As foilows(VIAQ, S.302,6.i); <br /> Each bedroom: Tested, screoned, controilable, ttirough-wall port (z 4 Sq, 1n}ro me exterior. ' <br /> � Each RecreaHon room:One wall port as specttfed for bedrooms. ` <br /> Other enclosed"habltable"rooms: One wal�port as specified lor bedrooms. <br /> Overail Uving arca: Ono wall port as specified torbedrooms. <br /> O p QOR(JCentrai torced air}arnace which'deiivers outside makeup air through ihe duciing system. - <br /> O p Q Facessed Oghting fixtures(S:SD2.4:4)shall compry wl on�or moi,+. of the toliowing: <br /> � IC rated,with ao slots or holea in cans, oaulkod or seaied be4ween oan and ceiling <br /> �} IC rated wfth lable certifying an A5TM E283 tened dirieakago$ 2,D CFM : ` <br /> � Any UL listed tucture enoAsed by a 1/2"gypboard box or other manutacturetl box <br /> L w!1/2'clearanco to combustablos,and 3"clea�ance to`inaulation. ' <br /> WSEC Framing phase requirements: � <br /> Pafle 4 of G �nspected by Date <br />