My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3628 UPLAND AVE 2016-01-01 MF Import
>
Address Records
>
UPLAND AVE
>
3628
>
3628 UPLAND AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2017 8:10:21 AM
Creation date
3/8/2017 8:10:09 AM
Metadata
Fields
Template:
Address Document
Street Name
UPLAND AVE
Street Number
3628
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE � � � ' � ��� � ' <br /> � REQUIRED � <br /> tNSPecnoN IMPORTANT:Please su I Informatlon In the shaded boxes and check the a o rlate <br /> APPROVED PP Y PI • P <br /> � clrcies. Dlsregard topics that don't descrlbe your bullding or equlpment.p.Q �piace <br /> checks In the hti•o left coiumns. <br /> � r <br /> 0 <br /> ❑ ❑ Q Exterlor slab InsulaUon, il not located on the into�ior, shall be R-10 (Table 6-2). <br /> p p [2�i Exterlor slab Insulatlon, il present, shall approved for below grade use and protected atwve grade. <br /> p ❑ as Wells, inciuding rim joists, shali ba insulated without compression to(Table 6-2}: <br /> �R-;5 hatt (Options I,iq �:i-19 (Option IU, iv;v, vr,'vii� <br /> p ❑ Qinterfor below grade walis shall be insulated without compression to (Table 8•2J: <br /> �R-15 (Options I, ii) �R-19(Options III, IU,V,VI,VII} <br /> ❑ ❑ QVaulted cellings shali bc insulated without compression toA-30(Table 6-2, Atl options) <br /> p ❑ � Skyllght wall Insulatlon is installed and equivaient to the required wall R-values above. <br /> p ❑ � Vapor retarders sh�.it be installatl toward the warm surface as represented below(502.1.6): <br /> Select one opfron for tloors, wa�ls, and appropriate ceilings: • <br /> Floors: Q Ply�noed Wt E�eriof glue Q Poiy(� d Mil) � Backed batts <br /> 4Jalis: Poly piastic(a 4 Miq (� Face-stapled, backed bafls Q'PVA paint . <br /> Ceiling:;: Not required where ventiiatio� space averages �i2"<bove insulation. <br /> �Fece siapled backed batts QPoly plastic (� 4 mil) �PVA pai�t <br /> ❑ ❑ � Heatinp system efflclency and slzing requirements shall he met as represemed below: <br /> ❑ ❑ 8 Heat Pump eNlclency shall be met under ihe tollowing compliance path (5.503.a): <br /> � Split system, alr source heat pump:HSPF� 6.8, COP >3.0 <br /> � Single pacl.;�gQ, air source heat pumpi NSPF a 6.6, COP>3.0 <br /> C� Water sourca heat pump:COP a 3.8 <br /> � Ground sourco haat pump COP� 3A <br /> ❑ ❑ �Central force•alr furnaco AFUE rating, as listed in the GAMA Director��, shall be: <br /> (�i .78 (Options I, Ii, IV,VI,Vlq �a ,88 (Option III}) �a.74 (Option V) <br /> ❑ ❑ �Non-central,combustlon heating systems shall have intermRent ignition <br /> ❑ ❑ � Maximum heating system output {150°!0 of desic�n heal load) is _8TU/hc (S.503.22) <br /> ❑ ❑ s High efficlency forcetl•alr(urnace (s 56,000 BTU/hr.output)may m2y exceed 150°Iool DHL <br /> because: QGAMA listed AFUE is z 78+ i per each SOOD BTU/hr output ihat it exCeeds the �HL. <br /> WSEC Insu/atlon phase requirements: � <br /> lnspected by: Date <br /> r ;., <br /> ", 6 � <br /> ❑ ❑ �Envelope Floors shall be insulated witiwut compression, and with support s 24"D.C.to: <br /> �Rt9 i0plions i, II, ill, IV, V) QR25 (OplionsVl, VII) <br /> p ❑ �Non•vaulted,attic celllnps shall be Insulated wi(hout compresslon to: See Table 6-2 <br /> �R-30(Options i, II, III, IV,V, Vil) 0 R38 (OpUon Vij �� <br /> ❑ p �i Door systems shall meek��U.40 (AII options) <br /> noor types are (�)___ _(2).______ (3) . <br /> Page 5 oi 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.