Laserfiche WebLink
� N <br /> ry.: '.:,;: � � <br /> - PUBL/C N/O/'�KS <br /> ���� .p�� �,.� ti � Da�,d ri'?�l,p <br /> � <br /> October 29, 1997 <br /> David Sharp <br /> 7312 59th Place NE <br /> Marysville WA 98270 <br /> Subject Owner. Sharp Building Corporation <br /> Job Address: 3628 Upland Avenue <br /> Plan Check No.: 56795 <br /> Dear Mr. Sh:irp: <br /> In response to the revision as submitted to your existing conscruction permit, your plans have been <br /> examined and you are advised that the permit is beina withhel� for the reasons listed below. These <br /> comments address building issues only, additional revisions ur additions may be required by other <br /> departments (such as Utilitics, Planning or Fire). All references refer to the I994 Uniform Building Code, <br /> as amended by the Statc of Washington and/or Washington State Energy Code 1995 Edition, unless stated <br /> otherwisc. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Div�sion with two copies of revisions retlecting necessary <br /> corrections. <br /> L Walls with unbalanced backfill exceeding 3'-6" and basement walls over 8'•0" tall are <br /> required to be designed by a licenscd Washington State structural engineer. <br /> 2. The engineering provided does not match the specifications shown on the plans. Provide <br /> lateral analysis prepared by a licensed Washinaron State structural engineer. Reference <br /> location of hold downs and shcar walls as specitied in engincering analysis on drawing set. If <br /> analysis prcpamd by enginecr is for only a portion of the building, the rest of the building is <br /> required to have all braced wall panels cleady marked. (2326.113 UBC) <br /> 3. Specify anchor bolt size nnd spacing at retaining conditions. <br /> 4. Providc tempered glass at required hazardous locations. (2406.4 UBC) <br /> 5. Provide a scction of thc brick venecr including toundation support and dimensions. Show the <br /> following: <br /> a. A I" airspace betwccn thc veneer and backing, 15H fclt and minimum No. 9 gauge <br /> approved typc nomcorrosive ties at 1 for each 2 squarc fcet of wall surface. Weep holes <br /> at thc lo�vest coursc. (1403.6.4.2.1) <br /> b. A maximum stud spacing of 16" on center for the wall anchuring th� brick veneer. <br /> (1 d03.6.4.2) <br /> c. A s��nno�e, other than wood, for the veneer over the garage door, windows and other <br /> doors. Show tLe lintel size. (2316.1) <br /> d. Consuuction of the brick column. Frovide reinforced conswction unless it is designed as <br /> u vcnccr occr a structural column. <br /> CITY OF EVERETT• 3200 Cedar Street • Everetl.WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />