Laserfiche WebLink
. • �� <br /> Page 4 of 4 <br /> C.O.E. # So/SG <br /> Date <br /> � Note on the drawings that all structural panel components of the house such as softwood, <br /> plywood, particle board, wafer board and oriented strand bosrd shell be identi6ed as <br /> "EXPOSURE 1", "EXT5RIOR" or"HL1D-APPROVED". 400.1 <br /> 1 l. Specify on the plans that all solid fuel buming appliances shall be provided with the following: <br /> a. Tight fitting giass or metnl doors. <br /> b. M outside source of combustion air directly connection to the firebox, or tested and listed <br /> per HUD carbon monoxide performance requirements. <br /> � Fireplaca shall be provided with each of the following: <br /> a. Tightly 6tting flue dampers, operated by a readily accessible manual or approve� automatic <br /> control. <br /> b. M outside source for combustion air-ducted into the 8rebox, a minimum of six square <br /> inches and an operable outside air duct damper. <br /> l3 Note on the plans that the builder shall provide a three month etched tract radon monitor, <br /> installation instructions and radon information sheets at the final inspection. <br /> ADDITIONAL COMMENTS <br /> Rev. I2-1 I-95 <br /> 1HI.LST.doc <br /> I <br />