Laserfiche WebLink
. <br />�k�� �.W <br />_ _ G .�.Yn• ' <br />, , ; p. , ..� '}` '� `;� .i «' �"' � <br />,�,.:�� .'rr:.�:, a:.�, _ ,.��.�.��.��^:��-�`. <br />February 25, 1971 <br />Sherwood 6 Roberts <br />P.O. Rox 2196 <br />Evere[t, Washington °8201 <br />Re: 2207 Virginia - Electrical Inspection <br />Dear Sir: <br />CITY OF <br />everett <br />CITV II�LI • i]9.P1�!] <br />fVC�ICR. N�<�. NGTfY <br />•ntJ <br />�N61`fCTION :�fV�Nlv['.' <br />An electrical i.nspection was made at [he above address as required <br />by F.l{,A, The following deficiencies were noted. All the lighting <br />outlets in the basement are the type tha[ ha� l.ive exposed parts. <br />These r.mst be changed [o an approved type. The florecen� lights <br />are not properly installed and wired vi[h an approved wire. <br />Addi[ional outle[s arc nceded as follows: onc additional outlet <br />needed in thc front reom, two cutlets needed in [he dinning room, <br />one additional outlet in the kitct�en and all must bc grounded and <br />hc on a u[ili[y cirui[. The fix[urc over [he sink mus[ be grounded. <br />,1 separatc grocnded outle[ is needed in the batLroom and the exis[ir.g <br />tir.tures must te grounded, F.ach of [he bedrooms must have [uo ou[- <br />lets, upstairs and down. <br />The main service appears to be of preper size for [he existing and <br />addicional load of [he above i[ems. <br />Yours [ruly <br />I.. J. Dougherty <br />Electrical Inspector <br />LJD:eb <br />