Laserfiche WebLink
� <br />� <br />FROM:CITY OF EUERETT B�DG llPT T0� 206 252 �317 hr'R 5, 1995 1'�35PM l�722 P.02 <br />11. CONSTRjJCTfON bOC 1 1�NTS <br />'1'hre.e (3) completc sets with site plans. �4inimum scale: 1/8" = 1'-0". <br />A. Architecl's sl�mp. All projccts of a,000 square feet or more than q dweiling <br />units require the plans to bc prepared by an architect currently liccnscd to pr;�ctice <br />in the state of Washington QtCW 18.08) - Ylease note that an engineer's stimp <br />does not climinate lhis requiremr.nt. <br />B. Floor plan with complGe dimensiont (indicate entire buiiding showing ail exit <br />doors, s�airs, corridors, etc.). <br />C. Building seclion with vcrtical dimcnsions indicating location of tcnnnt <br />improvcmcnt, othcr tenants and building construction. <br />U. Wall sections indicating proposcd construction and assembly rating as rcquired <br />for occupancy separafion, �rca scparation or building construction. <br />L•. Stair or ramp plans (1/4" == 1'-0" minimum scale) nnd sections. <br />P. 9'oilet room plans (]/4" = 1'-p" minimum scale) and interior elcvations indicllc <br />wall and floM finishes, fixturc. dimcnsions, handicap accessories (if required) and <br />toilct acccssories. <br />G. Door schcdule (indicale framr. and doc�r rating, type of lock or latch and signa�;e. <br />if required), <br />H. Lighting p)an and energy budgct caiculations (indicate wattage of all fixtures, <br />include exterior building mountcd lighting if added or revisecf). '!'his must bc <br />provided at thc timc of Uuilding permit application. <br />I. �nergy calculations (any exlerior wall or roof of existing buildings must bc <br />insulateci when the frammg cnvity is exposecl when remodeling. Caviry must bc <br />insulated to the maximum dcpth possible or ro the dcpth indic�ted by energy <br />calculations). <br />7. Structural dra�aings and calcidatiom (only required if altering existing shucturc <br />or adding ncw Ioad-hcaring struclure). <br />I�. Copics of any permits/�pprovals issucd by the Planning Depa�•hncnt. <br />p.nu<l.� Innunrv 71, 194$ <br />