Laserfiche WebLink
COMPLIANCE <br />REQUIRED V <br />INSPECTION I IMPORTANT: Supply Information and check appropriate circles In the shaded boxes. <br />APPROVED Disregard topics that don't describe your building or equipment. DO NCT place checks In <br />the two left columns. <br />O O rz Exhaust ventilation shall be provided for each dwelling unit as follows (VIAQ S. 303): <br />Location <br />Minimum at .25 w.g. Mfr./model <br />Fan label CFM(.1 W.G.) <br />Kitchen fan <br />100 CFM <br />Bathroom fan( <br />) <br />50 CFM <br />Bathroom fan( <br />) <br />50CFM <br />Bathroom fan( <br />) <br />50 CFM <br />Laundry fan <br />50 CFM <br />9 Whole house fan' <br />(choose one) <br />Q 50 CFM (1-2 bedrms) <br />Q 80 CFM (3 bedrms) <br />Q 100 CFM (4 bedrms) <br />WholehouseYan: Location, Sone'rating (5 1.5If'attictancl)serthan 4'to <br />ceiling) <br />8 Whole house fan is Ilsted/labled "for Continuous use'. <br />Whole house fan wiring for control routed to central location fdetwmidistat only). <br />O O 18 •Whole house fan also serves as a kitchen or bath spot fan. Q Yes QNo <br />It a spot fan is designated as a whole house fan, the capacity shall be the larger CFM requirement. <br />O O Qo Whole house fan shall run Continuously: Kit,,' en (25CFM); Bath`€ laund. (20CFM) QYes Q No: <br />CAS O Q Integrated forced -air furnace ventilation (IAQ Code, S. 303.12(b)) shall be synchronized with a <br />whole house fan to §upply fresh air to,the dwelling: Q Yes Q No <br />Q It yes, a 6' outside air Inlet dud w/ motorized damper run from the building exterior to to <br />the furnace return plenum and, limit the vehtiftion rate to between .35 - .50 Air Changes <br />/Hour.Q Modifications to the above Integrated <br />a' <br />manner acceptable to the Building Official, to demonstrate .35 -.5 air changes per hour. <br />ED O Mechanical ventilation fan ducts shall be z 4" and properly sized (VIAQ,Tabie 3.3). <br />C3 L7 QQ Fresh air shall be provided for each dwelling unit as follows (VIAO, S. 302.6,1): <br />Each bedro0ln::Tested, screened, controllable, through -wall port (2 4 Sq. in.) to the exterior. <br />Q F Each Recreation room: One wail port as specified for bedrooms. <br />I Other enclosed "habitable" rooms. One wall port as specified for bedrooms. <br />/ L Overall living area: One wail port as specified for bedrooms. <br />r O QOR QCentral forced air furnace which delivers outside makeup air through the ducting system. <br />I= O Q Recessed fighting fixtures (S.:502.4.4) shall comply w/ one or more of the following: <br />Q IC rated, with no slots or holes in cans, caulked or sealed between can and ceiling <br />IQ iC rated with table certifying an ASTM E2B3 tested aldeakage _< 2,0 CFM <br />Q Any t1L listed fixture enclosed by a 112" gypboard box or other manufactured box <br />wi 112' clearance to combnstables, and 3" clearance to insulstion. <br />�WSEC Framing phase requirements: <br />Page 4 of 6 inspected by Date <br />