My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4602 W VIEW DR 2018-01-02 MF Import
>
Address Records
>
W VIEW DR
>
4602
>
4602 W VIEW DR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2022 3:09:58 PM
Creation date
3/8/2017 12:55:16 PM
Metadata
Fields
Template:
Address Document
Street Name
W VIEW DR
Street Number
4602
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
COMPLIANCE ' <br />REQUIRED N <br />INSPECTION IMPORTANT: DO NOT place checks In the two Jett Columns. <br />APPROVED <br />❑ ❑ Q Exposed foam Insulation shall comply as follows (S. 502.1.4.7): <br />❑ Protected with metal or plastic flashing, or other suitable material that extends below grade. <br />❑ Insulation is approved for sub -grade, exterior use and property Installed. <br />❑ ❑ ®Airflow between fresh air ports and the whole -house fan ensured by undercut doors/gdlis(VIAQ,S. 302.6.4) <br />❑ ❑ ©i Looseflll !nsulation OK if (S.502.1.4.5): <br />❑ maximum ceiling slope not > 3 in 12 <br />❑a 30' of clear distance from top of bottom chord to underside of roof sheathing at the roof ridge. <br />❑ ❑ mil black polyethylene ground corer, shall be lapped 12" at Joints and extend to foundation wall <br />❑ [3 Clearances shall meet listed minimums between insulation and (S.502.1.4.3): <br />❑ chimney ❑Non -IC rated recessed lights: 1/2" to combustables, 3" to Insulation. <br />❑ ❑ EDAttic hatch shall be insulated to required ceiling R-value and is wealherstripped (S.502.1.4.4) <br />❑ ❑ @flAffIc access shall have wood dam or equivalent to retain loose fill insulation in attic(S. 502.1.4.4) <br />❑ ❑ W9 1AII exterior doors (except 20 minute doors) shall be weatherstripped (S. 502.4.3). <br />❑ ID Service hot & cold water piping in unconditioned spaces shall be Insulated to R-3(S. 503.11) <br />❑ [3 r Service recirculation hot water piping in unconditioned spaces shall be insulated to Table 5-12 levels. <br />❑ ❑ @Heat pump thermostat shall have progamable capability (S. 503.8.3.5) <br />❑ ❑ UJThermostat provided for each HVAC system with range of 55-75' F.(heating) (S.503.8.1.1). <br />❑ ❑ Readily accessible, automatic or Manual means provided to restrict or shut-off Heating input to each <br />zone or floor during periods not requiring heat (S. 503.8.3.1). <br />❑ ❑ @DControls for backup heat prohibit similtaneous operation of the primary system (S. 503.2.2(3)). <br />❑ ❑ s hanical ventilation system shall have proper timers, and/or switches (VIAQ, S. 302.3). <br />El ❑ <br />a chemical ventilation ducts shall have R-4 insulation in unconditlon .d spaces (VIAQ, S. 302.5) <br />❑ ❑ a chanlcal ventilation supply ducts in nonditioned spaces shall have R-4 insulation (VIAO, 302.5) <br />❑ Elupply ducts shall have volume dampers, or the equivalent, to balance system (S. 503.6). <br />❑ [3upply and return air ducts shall have sealed duct joints in unconditioned spaces (S. 503.10.2). <br />Elr ❑ VAC plenums, supply, and return silt ducts shall have R-8 insulation (Table 5-11, All options) <br />❑ ❑ z Iectric water heater(s) shall have (S. 504.2.1. 504.3, 504.4) : <br />❑ separate power . shut-off ❑ 1987 NAECA Lable on tank <br />❑ noncompressible R10 pad (unheated spaces only) ❑ Temperature setting s 120 F. <br />❑ ❑ showers and lavatories shall limit flow to c 3.0 gallons/minute (S. 504.8.1). <br />❑ ❑Swimming pools(S.504.5) shall have: <br />❑ readily accessible ON/OFF switch (pump, heater) ❑Pool cover ❑Piping insulated to S. 503.11 <br />O ❑ Ail fireplaces (VIAQ, S. 402.3) shall have: <br />❑ 6 square inch combustion air supplyduct w/ accessible damper directly connected to the fire box <br />ri Tight fitting glass or metal doors. ❑ Tight fitting flue damper <br />L3 ❑ e Solid fuel burning appliance(s) (VIAQ, S. 402.2) shall have: <br />❑Tight fitting glass or metal doors <br />❑Outside combustion air source directly connected to the fire box <br />❑Exception: Non -direct, 4" diameter, dampered, combustion air source: allowed only for (1) new stove <br />installations in existing homes where obstructionsprecludes direct combustion air, or (2) Central <br />heating systems located in unheated spaces. <br />❑ p FD Three month, etched track radon monitor, printed instructions, and information sheets shall be supplied <br />to the single family dwelling or first floor units of multi -family dwellings by the general contractor (VIAO,S. <br />502.2.1), <br />WSEC Final phase requirements: <br />Inspecttai by <br />Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.