My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1918 WALL ST 2018-01-02 MF Import
>
Address Records
>
WALL ST
>
1918
>
1918 WALL ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 11:40:40 AM
Creation date
3/8/2017 1:26:51 PM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1918
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
769
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Memorandum <br />WMFL Project No. 8105.02 <br />Page 2 <br />December 21. 1983 <br />7. Design complies with 15-minute thermal barrier on room side <br />of the foam plastic insulation. Pre -manufactured walk-in <br />coolers and freezers meet all requirements of Section 1717 <br />UBC, per phone conversation with Bob Westlund, of Volrath Co. <br />in Seattle (206/771-5643). <br />9. See Item 5 in Section A above. <br />12. Review and approval of the automatic sprinkler system by a <br />"rating bureau" is not required, but can be done if desired <br />by the County, at County expense. <br />14. Both items a and b require review and approval by the Everett <br />Building Department. <br />26. Agree. Contractor will be notified. <br />0. Exit Comments <br />1. Review and approval by Everett Building Department required. <br />Preliminary indications from the Building Department were <br />that Stairway N2 was acceptable for a smokeproof enclosure as <br />designed. Note: 1982 UBC allows smokeproof enclosures to be <br />omitted if all exit stairways are pressurized and provided <br />with a relief opening. <br />2. Security design demands alternates, therefore, building okay <br />as designed. <br />3. Disagree. Cutdoor recreation rooms 501 and 572 must be <br />considered as "outdoor." They are "roofed" by a security <br />screen only and are open to fresh air and the elements. <br />7. Review of entire booking area required by Everett City <br />Building Department. <br />8. b. Disagree. Stair enclosure discharges directly outside. <br />Corridor 157 and door 156 are not pa,t of the 2-hour stair <br />exit enclosure. <br />c. Disagree. However, if the reviewing authority insists <br />on this change, it won't be a major problem to revise. <br />Change Order required. <br />12. Doors in the medical service and housing areas should swing <br />into the corridor for security reasons. The overriding <br />concern here is to prevent inmates from barricading <br />themselves in the various rooms where staff might not be able <br />to gain access. <br />
The URL can be used to link to this page
Your browser does not support the video tag.