Laserfiche WebLink
+. 7/1/71 DEPARTMENT OF HOUSING AND URDAN DEVELOPMENT <br />HUD -FHA SEATTLE AREA OFFICE <br />di:iJ(„1 '_J CJ:•i1Tn?NT FHA CASE <br />TE_ i i'% - z <br />SHEET—Oi S <br />ecific cc.^-it=nt condition[ (applicable when checked) <br />te: Cc::Gi_iona 1 through 10 are on FHA Commitment Form 2800-5. <br />All required repairs must be completed in a professional manner. <br />et <br />. 0 Inat;.11 as acceptable vapor barrier ground cover over entire crawl apace area. <br />Q Cr .a cp.:ce shall be graded and sloped to prevent pending of seepage water, ivat::li <br />dra_n Zile in gravel bed connected to suitable outfall to provide positive dru.nc?o <br />cucy from dwelling. Cover entire crawl space with acceptable vapor barrier. <br />Install at least four 8'kAIV galvanized hardware cloth screened crawl space are <br />van --a of V sash (one near each corner) to adequately vent crawl space area, <br />::ate: btatal louvered nail on vents are not acceptable. 1vdG je (il�c•r,,.d -j c7 :,..` <br />P:rr_,a concrete foundation and/or piers under all wood &ilia, ponts cad pupportin,, <br />c. era under dwelling so that no wood remains within 6" of the ground, <br />°epl.ce all deteriorated rotted or damaged wood foundation and frami:i; ou%oc, <br />incl:d ug posts, plates, beams and joists in underfloor area, with sound matari:i. <br />iio .,uos to remain within 6" of ground. <br />=1Ia) Rcplaco. all skirting and other wood in contact with the ground and renlacc <br />cLc'., - tarial resistant to rot and infestation. Finish all exposed new or repaired <br />vo:k to catch exterior. No wood to remain within 6" of ground. <br />�r <br />Sub::it certification from a state licensed peat control operator that wood destroy!::, - <br />organ a cs, fungus and/or rot damage in the structure of the dwelling has been <br />alit:nctad. A "Standard Notice of Work Completed" or a report Form tnuicntin- no <br />:af-azatioa may oe submitted as certification. Note: All repairs must be couplet fl <br />in conformance with local professional building standards and local building codes. <br />/7 ;.cove all debris, including wood scraps, form boards, etc., from under buildinJ. <br />(-/ Trim bushes, cut weeds and remove all junk and debris from prenises. <br />Q Inctcll a 3/4" non-adjustable temperature and pressure relief valve on hot ,,afar <br />and a 3/4" discharge line to outside or to an interior drain. Rating of valve shall not <br />b,: greater than pressure rating of water tank. <br />:,Q rurniah evidence from the local health authority indicating approval of the <br />L7 individual water supply system, Q individual sewage disposal system. <br />,L7 tnstall elbows for.doonspouta and provide splash blocks to carry roof water at least <br />hire& fc•x quay fro.& foundation. <br />ace gutters ut:der all eaves on main building. Provide adequate downsp•,utc <br />;..d a;?lasa blocks. Apply primer and two coats of exterior paint to match eXiacia; <br />t <br />/ Clc:a out and repair gutters and downspouts so they function properly. <br />1/8" screened hooded roof or 1/3" Screened louvre gable vents to provide p0a.,1VC <br />Czo>a v ntilation of attic apace. <br />cew gas or electric _gallon water heater with 3/4" nun -adjustable tc:gxratur: <br />'i and cresaure relief valve Jith discharge line to outside or interior drain. <br />c U1iJwEnt not acceptable. <br />V z.. <br />4 <br />