My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2410 WALNUT ST 2018-01-02 MF Import
>
Address Records
>
WALNUT ST
>
2410
>
2410 WALNUT ST 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 2:54:09 PM
Creation date
3/8/2017 2:11:27 PM
Metadata
Fields
Template:
Address Document
Street Name
WALNUT ST
Street Number
2410
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
153
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXTERIOR ELEVATION NOTES <br />1. The grade at the foundation falls away from the <br />building a min. of 6" within the first 10'. Minimum slope 5% <br />where less than 6" fall in 10'. <br />2. Hold exterior Finish materials 6" abv. finish grade (R317.1). <br />3. All wood exposed to weather shall be pressure treated or cedar. <br />4. Wood trim at all openings per olev. <br />5. All exterior door and windows, penetrations, joints, and <br />openings caulked or weather-stripped for air leakage <br />6. Flash and counterflash all exterior openings. <br />7. G.I. flashing at all valleys and roof to wall connections. <br />T 1-11 <br />Siding <br />----- __------ ---------------- --_ <br />L— — — — — - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ——J <br />�—__--_ ------------- —_—ti <br />SIDE EXTERIOR ELEVATIONS <br />114" = 1'-0" <br />Composition Roofing (6:12) <br />NEWlllll� <br />REAR EXTERIOR ELEVATION <br />114" - V-0" (faces Duplex) <br />FRONT EXTERIOR ELEVATION <br />1/4" = V-0" <br />GRADING and DRAINAGE <br />1. Provisions shall be made for the control and drainage of surface <br />water around the buildings bygutters. dram lines, inlets. and catch <br />basins or other necessary drainage structures and shall be installed <br />where worm water disposal cannot be obtained Without their use or <br />where erosion cannot be prevented by finish grading and planting. <br />Dry wells shall not be installed in areas where the soil is not well drained <br />and/or porous. <br />2. Grading shall be provided to insure. <br />a ) Diversion of water away from the building. <br />b.) Prevention of standing water and soil saturation detrimental to <br />structures and lot use <br />c.) That natural drainage channels or basins are not blocked or Filed. <br />d.) Provisions tot the disposal of water from a lot - <br />e ) Protection of adjoining property. <br />APPLICABLE CODES <br />20121NT'L RESIDENTIAL CODE (IRC) <br />WAC 51 51 <br />20121NT'L FIRE CODE (IFC) <br />WAC 51 54 <br />2008 NATIONAL ELECTRICAL CODE (NEC) <br />WAC 296 46B.010 <br />2012 UNIFORM PLUMBING CODE (UPC) <br />WAC 51.56.51.57 <br />20121NT'L ENERGY CONSERVATION CODE (IECC) <br />WAC 51.11R <br />2012 WA. STATE ENERGY CODE (WSEQ <br />CITY OF EVERETT DESIGN d CONSTRUCTION <br />STANDARDS 8 SPEC'S <br />INDEX OF DRAWINGS <br />A-1 EXTERIOR ELEVATIONS <br />A-2 FOUNDATION PLAN <br />A•3 FLOOR PLAN and WALL SECTION <br />O <br />U j O <br />m ON <br />U�3 <br />D O <br />3 N j <br />a W <br />G <br />0 <br />H <br />I n <br />0 <br />e E <br />c a <br />ozm= <br />q <br />gip'^ E <br />P <br />n O 6 g p <br />n <br />a °[unto <br />l7 d p <br />Yw �° <br />� E <br />0 <br />DATE: <br />5/14/2014 <br />SCALE: <br />SHEET: <br />A-1 <br />01� <br />
The URL can be used to link to this page
Your browser does not support the video tag.