Laserfiche WebLink
FN DESCRIPTION QTY <br /> 1 30" CRICKET LETTERSET 1 <br /> 2 03/8" [10] S.S. THREADED ROD W 12" [305] LONG W/ HARDWARE 27 <br /> 5" [127] 3 POWER SUPPLIES (AS REQUIRED PER LED LAYOUT) A/R <br /> 11'-1" [3378] rA 4 WEATHERPROOF POWER SUPPLY ENCLOSURE 1 <br /> 5 PAIGE 18" 1457 WALL FEED THROUGH PROTECTION TUBE 8 <br /> 6 .50"ODx.26.IDx1/2" LONG BLACK PLASTIC UNTHREADED SPACER - PART #180 27 <br /> 7 TOUCH-UP PAINT A/R <br /> " 8 POUNCE PATTERN (SEND FULL-SIZE PAPER COPY OF MOUNTING PATTERN) 1 <br /> ° 9 CARDBOARD BOXES (PACKAGE INSTALL KIT, EXCEPT POUNCE PATTERN) A/R <br /> 10 CARDBOARD TUBE (PACKAGE POUNCE PATTERN) 1 <br /> I <br /> ----"'N <br /> 11 INSTALL DRAWING 1 <br /> r.N n \\\` <br /> CD _ 0 0 0 <br /> to 0 <br /> N <br /> PRINCIPLE 360 LABEL <br /> oT1 IUL LABEL <br /> i <br /> " o o " IC Alliii " o 0 5" [127] 040" ALUMINUM <br /> LETTER RETURN <br /> FABRICATED ALUMINUM 07/8" ELECTRICAL THIS LETTER SECTION GREEN VINYL, 0-53" MOUNTING HOLE <br /> CHANNEL LETTER ENTRANCE HOLE (TYP) ALL OTHER LETTER SECTIONS TO BE (T') <br /> BLACK DUAL COLOR POWER SUPPLY HOUSING <br /> ELEVATION VIEW SIDE VIEW 080 BRAKEFORMED ALUMINUM <br /> ENCLOSURE WITH WATERPROOF -I 1" JEWELITE TRIM CAP <br /> INSTALLATION INSTRUCTIONS: COVER tedrEE r rli is II <br /> in <br /> 1. SECURE POUNCE PATTERN TO WALL <br /> 2. DRILL MOUNTING AND ELECTRICAL HOLES INTO WALL. <br /> 3. INSTALL LED CABLE PROTECTION TUBES (187457mm LONG) INTO THE REAR OF 120V POWER SUPPLY <br /> SIGN. PUSH THE BEVELED END OF EACH PROTECTION TUBE INTO REAR OF EACH <br /> LOCKING BUSHING UNTIL YOU HEAR AND FEEL THE TWO LOCK TOGETHER. 3/16" WHITE <br /> 4. ADD A BEAD OF NON-HARDENING CAULK AROUND EACH PROTECTION TUBE AND I <br /> ACRYLIC LETTER <br /> ON TOP OF THE LOCKING BUSHING HEX TO INSURE WATER TIGHTNESS. FACE <br /> 5. ADD A BEAD OF NON-HARDENING CAULK AROUND EACH HOLE WHERE MOUNTING <br /> HARDWARE PENETRATES THE WALL TO INSURE WATER TIGHTNESS. E <br /> 6. MOUNT LETTERS TO WALL AS SHOWN. MAKE SURE NO WATER CAN PENETRATE ••"'a <br /> LETTERS BETWEEN SECTIONS. S.S. 'MOUNTING HARDWARE CHART ALL ELECTRICAL CONNECTIONS �a�' I SUPPLY WIRE <br /> 7. BEHIND THE WALL, TRIM THE PROTECTION TUBES TO FIT WALL THICKNESS. BE Q�// BY INSTALLER __ <br /> CAREFUL NOT TO DAMAGE LED CABLE. op Qy r <br /> 8. MOUNT POWER SUPPLY HOUSING INSIDE BUILDING OPPOSITE SIGN SECTIONS. �O �� `r I� <br /> 9. MAKE ALL SECONDARY AND PRIMARY ELECTRICAL CONNECTIONS. <br /> 10.TEST LJGHT SIGN. 348 8t1LTS U WALL * * r <br /> iiii <br /> 11.ATTACH WIRE AND POWER SUPPLY COVERS. 3/8!tAGSWSHIELOS "; %rie <br /> 12. CLEAN SITE OF ALL INSTALLATION DEBRIS. 3/8" LAG BOLTS * 1114� _ � <br /> 13. INSTALLATION TO MEET ALL CODE REQUIREMENTS. 3/8" TOGGLE BOLTS * _ I PAIGE WALL BUSTER CONDUIT <br /> THRU WALL Cr 18" (457) <br /> %NWI LONG & PAIGE LED RIP STRIP <br /> DIMENSIONS ON THIS DRAWING ARE DISPLAYED PAIGE LED RIP STRIP W/ GROUND =1 WITH GROUND (6 FT TAILS) <br /> IN ENGLISH UNITS FOLLOWED BY METRIC UNITS <br /> li <br /> IN BRACKETS. ALL METRIC UNITS HAVE BEEN evil r <br /> ROUNDED TO THE NEAREST WHOLE MILLIMETER. r , <br /> 4100 <br /> Il <br /> r AGILIGHT WHITE <br /> Inei <br /> liar <br /> CRATES AND WEIGHTS 1r/ <br /> AREA: 27.7 SQ FT (2.6 SQ METERS) r LED MODULE <br /> ESTIMATED CRATED VOLUME: 34.1 CUBIC FT (0.97 CUBIC M) CONDUIT TO r <br /> CONSTRUCTION & INSTALLATION OF ESTIMATED CRATED WEIGHT: 84 LBS (37.7 kg) PRIMARY ELECTRICAL SOURCE <br /> Il 1 <br /> CHANNEL LETTERS SHALL CONFORM EST)MATED UNCRATED WEIGHT: 28 LBS (12.6 kg) <br /> TO ALL UL, NEC, CSA AND LOCAL i <br /> CODES , .063 ALUMINUM <br /> LETTER BACK <br /> SIGN ELECTRICAL INFORMATION I <br /> LEDs: (51) AGILIGHT LS-PRO160-65K-2B1 LEDs CAULK INSIDE ALL LETTERS <br /> LED POWER SUPPLY: (1) AGILIGHT PS12-60WSL-100-277V IiiIIII IIII W/ BLACK SILICONE CAULK <br /> POUNCE PATTERN SHALL BE SUPPLIED TOTAL CONNECTION LOAD: .95A ® 120V s <br /> BY LETTERSET MANUFACTURER. CIRCUITS REQUIRED: (1) 20 AMP <br /> lir1 J� <br /> ALL ELECTRICAL COMPONENTS TO BE UL LISTED <br /> GROUNDING PER UL AND NEC SPECIFICATIONS <br /> 1/4" DIA. WEEP HOLE <br /> WITH LIGHT COVER <br /> SECURE W/ 03/8" S.S. MECHANICAL PART #180 <br /> FASTENER AS REQUIRED PER SITE 50" OD x .26" ID x 1/2" LONG <br /> CRICKET CR -FL -30R (INSTALL) CONDITIONS BLACK PLASTIC UNTHREADED SPACER <br /> 30 7, BLACK FACE-LIT CHANNEL L E T T hI1R iJ LETTER SECTION DETAIL <br /> Principle Group The following document is for design intent _ ____ ___ _ P r(O n dO�aQ B <br /> 2035 Lakeside Centre Way purposes only and is the intellectual property _ ____ ___ _ Latest Revision: <br /> of Principle Group. It shall not be reproduced <br /> S u i t e 250 - ---- --- - Drawing by:JLS Date:06/16/2014 <br /> and/or distributed for any purpose without prior _ ____ ___ _ <br /> 0 o K n o x v i l l e, T N 3 7 9 2 2 written approval. The manufacturer shall be <br /> o Main: 8 6 5.6 9 2.4 0 5 8 responsible for all structural, electrical, - ---- --- - Description: 30 BLACK FACE-UT CHANNEL LETTERS <br /> JU��u f� v� I'll mechanical, and foundation engineering. B 11-24-14 JLS CHANGED LOCATION OF MOUNTING HOLES TO MATCH ACROSS EACH LETTER VERSION <br /> — Toll–free: 8 7 7.6 9 2.4 0 5 8 These documents were not produced under an A 9-16-14 JLS REVISED LETTER SECTION DETAIL Customer: CRICKET <br /> www.principleglobal.com engineering services agreement. RTP 6-19-14 JHP DRAWING CHECKED & APPROVED <br /> Rev Date initials Description of change Sht 1 of 1 Drawing: C 0 9 3 6 81 <br /> (43L <br />