My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11014 19TH AVE SE CRICKET WIRELESS 2017-04-10
>
Address Records
>
19TH AVE SE
>
11014
>
CRICKET WIRELESS
>
11014 19TH AVE SE CRICKET WIRELESS 2017-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2017 8:10:52 AM
Creation date
3/8/2017 4:07:09 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
11014
Tenant Name
CRICKET WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FN DESCRIPTION QTY <br /> 1 30" CRICKET LETTERSET 1 <br /> 2 03/8" [10] S.S. THREADED ROD W 12" [305] LONG W/ HARDWARE 27 <br /> 5" [127] 3 POWER SUPPLIES (AS REQUIRED PER LED LAYOUT) A/R <br /> 11'-1" [3378] rA 4 WEATHERPROOF POWER SUPPLY ENCLOSURE 1 <br /> 5 PAIGE 18" 1457 WALL FEED THROUGH PROTECTION TUBE 8 <br /> 6 .50"ODx.26.IDx1/2" LONG BLACK PLASTIC UNTHREADED SPACER - PART #180 27 <br /> 7 TOUCH-UP PAINT A/R <br /> " 8 POUNCE PATTERN (SEND FULL-SIZE PAPER COPY OF MOUNTING PATTERN) 1 <br /> ° 9 CARDBOARD BOXES (PACKAGE INSTALL KIT, EXCEPT POUNCE PATTERN) A/R <br /> 10 CARDBOARD TUBE (PACKAGE POUNCE PATTERN) 1 <br /> I <br /> ----"'N <br /> 11 INSTALL DRAWING 1 <br /> r.N n \\\` <br /> CD _ 0 0 0 <br /> to 0 <br /> N <br /> PRINCIPLE 360 LABEL <br /> oT1 IUL LABEL <br /> i <br /> " o o " IC Alliii " o 0 5" [127] 040" ALUMINUM <br /> LETTER RETURN <br /> FABRICATED ALUMINUM 07/8" ELECTRICAL THIS LETTER SECTION GREEN VINYL, 0-53" MOUNTING HOLE <br /> CHANNEL LETTER ENTRANCE HOLE (TYP) ALL OTHER LETTER SECTIONS TO BE (T') <br /> BLACK DUAL COLOR POWER SUPPLY HOUSING <br /> ELEVATION VIEW SIDE VIEW 080 BRAKEFORMED ALUMINUM <br /> ENCLOSURE WITH WATERPROOF -I 1" JEWELITE TRIM CAP <br /> INSTALLATION INSTRUCTIONS: COVER tedrEE r rli is II <br /> in <br /> 1. SECURE POUNCE PATTERN TO WALL <br /> 2. DRILL MOUNTING AND ELECTRICAL HOLES INTO WALL. <br /> 3. INSTALL LED CABLE PROTECTION TUBES (187457mm LONG) INTO THE REAR OF 120V POWER SUPPLY <br /> SIGN. PUSH THE BEVELED END OF EACH PROTECTION TUBE INTO REAR OF EACH <br /> LOCKING BUSHING UNTIL YOU HEAR AND FEEL THE TWO LOCK TOGETHER. 3/16" WHITE <br /> 4. ADD A BEAD OF NON-HARDENING CAULK AROUND EACH PROTECTION TUBE AND I <br /> ACRYLIC LETTER <br /> ON TOP OF THE LOCKING BUSHING HEX TO INSURE WATER TIGHTNESS. FACE <br /> 5. ADD A BEAD OF NON-HARDENING CAULK AROUND EACH HOLE WHERE MOUNTING <br /> HARDWARE PENETRATES THE WALL TO INSURE WATER TIGHTNESS. E <br /> 6. MOUNT LETTERS TO WALL AS SHOWN. MAKE SURE NO WATER CAN PENETRATE ••"'a <br /> LETTERS BETWEEN SECTIONS. S.S. 'MOUNTING HARDWARE CHART ALL ELECTRICAL CONNECTIONS �a�' I SUPPLY WIRE <br /> 7. BEHIND THE WALL, TRIM THE PROTECTION TUBES TO FIT WALL THICKNESS. BE Q�// BY INSTALLER __ <br /> CAREFUL NOT TO DAMAGE LED CABLE. op Qy r <br /> 8. MOUNT POWER SUPPLY HOUSING INSIDE BUILDING OPPOSITE SIGN SECTIONS. �O �� `r I� <br /> 9. MAKE ALL SECONDARY AND PRIMARY ELECTRICAL CONNECTIONS. <br /> 10.TEST LJGHT SIGN. 348 8t1LTS U WALL * * r <br /> iiii <br /> 11.ATTACH WIRE AND POWER SUPPLY COVERS. 3/8!tAGSWSHIELOS "; %rie <br /> 12. CLEAN SITE OF ALL INSTALLATION DEBRIS. 3/8" LAG BOLTS * 1114� _ � <br /> 13. INSTALLATION TO MEET ALL CODE REQUIREMENTS. 3/8" TOGGLE BOLTS * _ I PAIGE WALL BUSTER CONDUIT <br /> THRU WALL Cr 18" (457) <br /> %NWI LONG & PAIGE LED RIP STRIP <br /> DIMENSIONS ON THIS DRAWING ARE DISPLAYED PAIGE LED RIP STRIP W/ GROUND =1 WITH GROUND (6 FT TAILS) <br /> IN ENGLISH UNITS FOLLOWED BY METRIC UNITS <br /> li <br /> IN BRACKETS. ALL METRIC UNITS HAVE BEEN evil r <br /> ROUNDED TO THE NEAREST WHOLE MILLIMETER. r , <br /> 4100 <br /> Il <br /> r AGILIGHT WHITE <br /> Inei <br /> liar <br /> CRATES AND WEIGHTS 1r/ <br /> AREA: 27.7 SQ FT (2.6 SQ METERS) r LED MODULE <br /> ESTIMATED CRATED VOLUME: 34.1 CUBIC FT (0.97 CUBIC M) CONDUIT TO r <br /> CONSTRUCTION & INSTALLATION OF ESTIMATED CRATED WEIGHT: 84 LBS (37.7 kg) PRIMARY ELECTRICAL SOURCE <br /> Il 1 <br /> CHANNEL LETTERS SHALL CONFORM EST)MATED UNCRATED WEIGHT: 28 LBS (12.6 kg) <br /> TO ALL UL, NEC, CSA AND LOCAL i <br /> CODES , .063 ALUMINUM <br /> LETTER BACK <br /> SIGN ELECTRICAL INFORMATION I <br /> LEDs: (51) AGILIGHT LS-PRO160-65K-2B1 LEDs CAULK INSIDE ALL LETTERS <br /> LED POWER SUPPLY: (1) AGILIGHT PS12-60WSL-100-277V IiiIIII IIII W/ BLACK SILICONE CAULK <br /> POUNCE PATTERN SHALL BE SUPPLIED TOTAL CONNECTION LOAD: .95A ® 120V s <br /> BY LETTERSET MANUFACTURER. CIRCUITS REQUIRED: (1) 20 AMP <br /> lir1 J� <br /> ALL ELECTRICAL COMPONENTS TO BE UL LISTED <br /> GROUNDING PER UL AND NEC SPECIFICATIONS <br /> 1/4" DIA. WEEP HOLE <br /> WITH LIGHT COVER <br /> SECURE W/ 03/8" S.S. MECHANICAL PART #180 <br /> FASTENER AS REQUIRED PER SITE 50" OD x .26" ID x 1/2" LONG <br /> CRICKET CR -FL -30R (INSTALL) CONDITIONS BLACK PLASTIC UNTHREADED SPACER <br /> 30 7, BLACK FACE-LIT CHANNEL L E T T hI1R iJ LETTER SECTION DETAIL <br /> Principle Group The following document is for design intent _ ____ ___ _ P r(O n dO�aQ B <br /> 2035 Lakeside Centre Way purposes only and is the intellectual property _ ____ ___ _ Latest Revision: <br /> of Principle Group. It shall not be reproduced <br /> S u i t e 250 - ---- --- - Drawing by:JLS Date:06/16/2014 <br /> and/or distributed for any purpose without prior _ ____ ___ _ <br /> 0 o K n o x v i l l e, T N 3 7 9 2 2 written approval. The manufacturer shall be <br /> o Main: 8 6 5.6 9 2.4 0 5 8 responsible for all structural, electrical, - ---- --- - Description: 30 BLACK FACE-UT CHANNEL LETTERS <br /> JU��u f� v� I'll mechanical, and foundation engineering. B 11-24-14 JLS CHANGED LOCATION OF MOUNTING HOLES TO MATCH ACROSS EACH LETTER VERSION <br /> — Toll–free: 8 7 7.6 9 2.4 0 5 8 These documents were not produced under an A 9-16-14 JLS REVISED LETTER SECTION DETAIL Customer: CRICKET <br /> www.principleglobal.com engineering services agreement. RTP 6-19-14 JHP DRAWING CHECKED & APPROVED <br /> Rev Date initials Description of change Sht 1 of 1 Drawing: C 0 9 3 6 81 <br /> (43L <br />
The URL can be used to link to this page
Your browser does not support the video tag.