My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8332 UPPER RIDGE RD A-B C-D 2016-01-01 MF Import
>
Address Records
>
UPPER RIDGE RD
>
8332
>
8332 UPPER RIDGE RD A-B C-D 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/24/2017 9:01:35 AM
Creation date
3/8/2017 5:05:41 PM
Metadata
Fields
Template:
Address Document
Street Name
UPPER RIDGE RD
Street Number
8332
Unit
A-B C-D
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ryan Construction <br /> Page 2 of 3 <br /> 6. The attached floor plan shows 2x12 F.J. at 16" O.C. where the original <br /> drawings show 14" deep floor trusses at 19.2" O.C. Clarify on all sheets of <br /> drawing set which rype(s) of construcuon aze to be used for this special <br /> project. <br /> 7. Delete all details and notes that aze not applicable to this project. <br /> 8. Provide 1'h"-2" diameter handrail up 34" min, 38" max above tread sing. <br /> Return ends. <br /> 9. Plans do not show the insulation level in the exterior walls. <br /> 10. Ceiling insulation is required to extend to the outer surface of the exterior <br /> walls. <br /> 11. When eave vents are installed, baffling of the vent openings shall be provided <br /> s.� as to deflect the incoming air above the surface of the insulation. The <br /> baffles shall be installed from the top of the ouuide of the exterior wall, <br /> extending inward, to a point six inches vertically above the height of <br /> noncompressed insulation, and twelve inches vertically above loose fill <br /> +nsulation. <br /> 12. Plans do not show how the requirements of the Washington State Ventilation <br /> and Indoor Air Quality Code (VIAQ) aze net. Show size and location of the <br /> whole house fan and all source specific fans. Show how oucside air is supplied <br /> to the dwelling (fresh air ports, integrated forced air). <br /> 13. Specify all posdbeam connections, posdfooting connections. A positive <br /> connection is required for uplift and lateral support. <br /> 14. The plans do not clearly show which windows are used at each location. <br /> Provide window schedule specifying size and location of all windows. <br /> I5. Show all posts on plan including built-up 2x members. <br /> 16. Provide non-combustible hearth at fireplace and specify type of fireplace <br /> proposed. Provide appropriate details andlor section drawings. <br /> In order for the processing of your application to continue, i[ will be necessary to <br /> provide the Building Division w�th two complete new se[s of drawings reflecting the <br /> corrections requested. <br /> Upon resubmittal of the drawings, your application will be given priority and plan <br /> review recommence. <br />
The URL can be used to link to this page
Your browser does not support the video tag.