Laserfiche WebLink
C' ' OI' EVERETT <br />BUILDING DEPART6fENT <br />DAT� Z-8-79 PLAN CORR�CTION SHEET PLAN CIIL•'CK N0. 79�161 <br />OWNER Larson Tr.ailer Equipment USE Trailer R�aris <br />CONTRIICTOR Same <br />ARCHITECT <br />JOB SITE ADDRESS 2939 Broadway <br />TYP� OF CONSTRUCTION III - N <br />USE 7,ONING g_; <br />FIRE ZONE 2 <br />OCCUPANCY GROUP <br />OCCUPANT LOAD <br />In response to your application for a�,ermit, your plans and specifications, <br />have been examined and you are advised that the issuance of a permit i� with- <br />held for the reasons hereinafter set forth. NOTE CAIt�PULLY: Answer questions <br />8nd make explanations DY CORRECTING ORIGINIIL PLANS, and new plans submitted <br />to the Department of Building and Inspection. (TIiIS S}IEET MUST IIE RETURNED <br />WITH OA.IGINAL PLANS AND SPECIFICATIONS UR TFIL•'Y �9ILL BE FILED AS NEW BUSINESS). <br />NO. <br />UNIFORM R[JILDZNG CODE 1973 EDITION <br />Reinfor�inq for piers between doors shown as 4-#5 vertical. <br />Show size and spacing of ties, <br />Detail of footing under above piers; <br />Indicate connection of 6 x 12 St4 to conc, Block piers. <br />Indicate connection of 6 x 12 BM to wood posts at centerlin <br />between pilasters on E, wall, Size of Posts. <br />Indicate connection of wood posts at concrete, <br />Show location of all bond beams <br />Show size and spacing of dowels connecting conerete block <br />to foundation. <br />Tyoe of mortar. <br />Tvoe of grout infill for reinforced cells .in blocks. <br />Concrete f.oundation wall reinforciny, <br />Connection of trus-joists to G x 12. <br />Trus-joists lateral bracing at exterior walls <br />Provide specifications for rooEinq - shall be fire retardan <br />Do you really need G" thick conc, floor slab7 <br />Why do you call for �4 @ 4'-0" o.c, each way in your concre <br />floor slab? <br />P71GE Or <br />CODE SEC. <br />