Laserfiche WebLink
• � <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> 5. Connect side sewer per City Standard#'s 601, 602, 604. <br /> 6. Connect all rooftop downspouls to the side sewer. <br /> �� Connecl rooflop downspouts to the drainage syslem provided for lhis lot. <br /> B. Rooftop runo(f must be discharged to a roof downspoul infiltration system per Ciry ot EvereR Storm <br /> Manual 3-2.6.2. Th,:approximale size trench is 3.5'wide, 2'deep and 25'long. See atlachment for <br /> more datails. <br /> �� The contractor musl meei wilh lhe Public Works Inspector to discuss polential drainage rouling prior to <br /> beginning the projecl. <br /> 10� Install erosion conlrol measures as determined by the Public Works inspeclor, such as sitl fence, slraw <br /> bales, swales,or erosion blankcts. <br /> 11. Inslall erosion conlrol measures per City of Everett Standards for small parcel� <br /> 12. Remove erosion control measures upon completion of the proj� ai prior to final approval o(the permit. <br /> -- _ --- -- ___ _ — — --- -- --.. _ _ _ — <br /> 13. All excavaled malerial from foundation, sidewalk and driveways shall be hauled lo an approved, <br /> permitled site. No waslinc�of material is allowed on lhis buildin� lot. <br /> 14 �� No dirt, mud, rocks or debris lo be lracked onto roadway. <br /> 15. No building malerials lo be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian lravel. <br /> 16. Adjust water meter box t"above sidewalk grade. <br /> 17. Remove and replace curb, gutter and sidewalk as per City of Everett Standard Plan#'s 305A 8 306 on <br /> lhis proposal's(ronlage as directed by the Public Works Inspector(i.e. aIl unused driveways and any <br /> broken or damac�ed area inusl be replaced). <br /> 1F1. Inslall a Type I concrete driveway per City of EvereU Slandard N307. <br /> � ,�1CCEY <br /> 19. ; Pave driveway from lhedre�+t property line oul to lhe skeel pavinc�. <br /> 20. Contact lhe Waler Dislricl for connectinc� provisions (or Uiis building's waler and <br /> sewer services. <br /> 21. A calch basin as per Cily Slandard Plan 1I402 wilh a gas Irap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. I(a sewer pump system is to be installed, Ihe pressure line must discharge inlo a privale manhole, then <br /> gravily(low across fhe public righl-of-way. <br /> 23. A sprinkler system is required for lhis building in compliance�vilh the requiremenls of NFDA Slandards <br /> 13D. <br /> Pi�Ccmnicnls 7� <br /> ( v <br />