My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2202 RUCKER AVE 2016-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2202
>
2202 RUCKER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2017 8:11:10 PM
Creation date
3/8/2017 8:10:59 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2202
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, _ , <br /> �°��T���'� STA'iE oF �EPARTMENT OF SOCIAL AND hrALTH SERVICES <br /> . 3 WASHINGTON a,�m�.,w++n:,9��, vesa <br /> ' �.., o�� Dixv t.ee N.y . <br /> . Go�ernor <br /> ,� . March 14, 1980 � <br /> t <br /> Ebby D. Davis, Manager <br /> __�var-U - ongregate Care Facility � <br /> ' 2202 Rucker � � <br /> Everett, Nashi gton 98201 ' <br /> t � Re: Ever-Dale Congregate Care Facility <br /> � Fire Sprinkler DraMings I <br /> � ' "`" CRU �{80033-1685-1 <br /> Dear Ebby Davis: <br /> The fire sprinkler drawings received February 14, 1980, have been revievred <br /> and are approved for construction subject to the State Fire Marshal's <br /> review. Approval is also subject to applicable code and field inspections. <br /> STATE FIRE MARSHAL'S REVIEW <br /> 1. Provide an approved inspectors Lest valve on third floor. <br /> (1978 NFPA, Standard 13, Section 3-9.1.1) <br /> 2, P�ovide an approved fire department siamese connection <br /> and contact local fire department as to location. (1978 <br /> NFPA, Sta�dard 13, Sectioe 2-7) ' <br /> 3. Provide current water flow test data at site size of city j <br /> main. (1978 NFPA, StandarA 13, Section 1-9.2) , <br /> ; <br /> 4. Provfde a 10-inch exterior alarm bell. (1978 NFPA, � <br /> Standard Section 3-17.4.1 and Section 3-17.4.2) <br /> I <br /> ' 5. The main control valve shall be provided with a super- <br /> vised tamper switch and arranyed to sound a local <br /> audible and visual alarm. (WAC 212-14-115) <br /> 6. The water flow switch shall bc connected to the build- <br /> ; ing fire alarm system and arranged to transmit an alarm <br /> to the local fire department. (NAC 212-14-115) <br /> 7. �dentify room and/or area occuaancy. Also any verticle <br /> hafts. (1978 NFPA Standard 13, Section 1-9) <br /> ' 8. I Combustible Hardrobe closets shall be sprinklered <br /> ' unless there is an 18-inch clear space between the <br /> ceiling and top of closet. <br /> 9. Provide a set of plans bearing the approval seal and p � � � <br /> any comments af the local fire official . <br /> �, � IJ �If 'J <br /> 10. Indicate location of nearest fire hydrant. ��a1� 1 <br /> C/�-y <br /> � i9A0 <br /> �.�15 l�s�Q o�y�REi r <br /> ,, fleDt. <br />
The URL can be used to link to this page
Your browser does not support the video tag.