Laserfiche WebLink
2. Ventilallon should be provided at the rate of 1.5 cubic feet per minute per square <br /> foot of gross Noor area for the enclosed parking levels per SecBon 1202.2.7. Note that <br /> this ventilatlon should be provided where no opening protection is required per Table <br /> 5-A. <br /> Comment noted. Please refer to revised drawings indicaUng requirement via <br /> reference notes and plan markings. <br /> R-I Occupancy <br /> 1. The first three floors of apartments aro required to have emergency egress <br /> windows or doors provided for each sleeping room which shall open direcdy into a <br /> public street, public alley, yard or exit court per Section 310.4. Based on these <br /> requirements, the following comments apply: <br /> a) All egress windows and doors should be labeled individually on the plans. <br /> Comment noted. Please refer to revised drawings indicadng requirement via l <br /> schedule notes and plan markings. <br /> b). Tha finished sill height of the egress windows should be shown to be no greater <br /> than 44 inches above the floor. <br /> Comment noted. Please refer to revised drawings indicating requirement via <br /> reference notes and plan markings. <br /> c). The den in Unit C and Unit E should be relabeled Bedroom' and be provided <br /> with an egress window or door, or have the closets removed. <br /> Comment noted. Please refer to revlsed drawings indicetlng compliance. <br /> d). The egress w?ndow fortn Unit A does not exit direcdy into the exit court, but into <br /> � pedestrian walkway. This should be revised. <br /> Comment noted. Please refer to revised drawings indicatlng requirement via <br /> reference notes and plan markings. <br /> 2. It should be specified that gypsum board backing used for tub or shower endosui as <br /> wiii be water resistant but will not be instalied on the ceiling as the framing exceeds <br /> 12' o.c. Section 2512 <br /> Comment noted. Please refer to revised drawings indicating requirement via <br /> reference notes. <br /> 3. The size and location of unit exhaust fans should be specified on the plans. <br /> Section 1203.3 <br /> „ , �� ���. :,��,��� ,.�,.,, <br /> � ',I+I �!h;l�:ll� i�.�„ i i �� �.��, r�„ <br /> . .. .. . . I�.\ q.ir I ii!1{111.r.Ya\ <br /> Ill��fRP�11111C!D�IpRD��GIIGR���CDQ�1�i�lIll��fEp��l�i,�RCHITECTUR� I�I��ERP�lI1�Cl�1}�RD��IIGRIP�f,D�fl���i�G�PE��GI <br />