My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2522 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
2522
>
2522 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/3/2019 8:57:37 AM
Creation date
3/8/2017 9:01:48 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2522
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
492
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NONSTRUCTCRAL <br /> General <br /> 1. The plans as submitted are incomplete. Additional comments may be required upon <br /> further�eview of subsequent submittals. If all comments are nut satisfied by tt�e end <br /> of the next submittal, an additional plan review fce per Sxtion 107.2 will be <br /> assesc•.1. Note that the comments of the cursory plan ceview letter of March 16, <br /> 19?8 which were either not addressed or were insufficient in reply have been listed <br /> again for compliance. <br /> 2. Based on ti;e request for an expedited plan review, and the breadth and depth of <br /> comments, this ncn-swctural portion of the review has been forwazded before the <br /> swctural portion of review has been started. The stiuctural plan review can only <br /> begin once the non-ewctural issues have bcen addressed. <br /> 3. The following design/build systems are submitted and approved as deferred <br /> submittals pro�•ided the comments noted per this review are sadsfied: Mechanical, <br /> Plumbing,Electrical and Fire Sprinkler Prouction. Section ]06.3.4.2 <br /> 4. The door and hardware schedule provided has proven very di�cult to locate <br /> appropriate doors quickly and accurately, and does not parallel indusuy standards. It <br /> is strongly suggested that each door shown be provided with a number that <br /> corresponds with a door number on the door schedule, and not be arr,�nged by room <br /> number first. The system shown may cause serious errors to be made in the field. <br /> 5. Fire protecdon shall be providcd for the building during construction. Details and <br /> procedives should be provided in accordance with Secdon 904.4 <br /> 6. Protection of pedestrians during conswcdon per Secdon 3303 is required. Details <br /> and requirements should be coordinated with the Kethy Fox, Public <br /> Services/Engineering Department,City of Everett, and the Civil Engineering Division <br /> of the Building Department,Ciry of Everott. <br /> 7. Changes in the submitted building may require a resubmission to the Planning <br /> Department, City of Eveatt for evaluation and compliance. Gary Doughty, Planning <br /> Department, (425)257-8731, should be contacted for the requi�ements. <br /> Allowable Area <br /> I. Floor area is the area included within the surtounding exterior walls of a building or <br /> portion thereof, ezclusive of vent shafts and courts. The floor aroa of a building, or <br /> portion thereof, not provided with su[rounding walis shall be the usable area under <br /> rhe horizontal projection of rhe roof or,floor above per Secdon 207. Based on this <br /> definition, the floor area of all decks and balconies, which have a deck, balcony or <br />