Laserfiche WebLink
Engineer's Inspection of the Property Located at Fe�e 7 <br /> 2618 and 262G ftucker Avenue, Everoti, Washington <br /> DeCay was found in this structure as noted in the paragraph tiiied "WOOD DECAI"' Iater in <br /> this seCtion of this report. ' <br /> ROOF STRUC7URE: On the exlerior oi the building, I tound no deformation of the steep <br /> poRion ot the roof structure that wouid give evidence of a serious structural deticiency. <br /> The rafters are ac4's, nominally Spaced 36 inches apart. No mid-span bracing is provided. <br /> The rafters do not have sufficient strength to support the loads for which such structures are <br /> normaly designed. <br /> Most older buildings, including this one, have roof structures that are significantiy weaker than <br /> those built to modern standarde. Until relatively recently, these buildings have been poorly <br /> insulated, or entirely uninsulated. This lack of insuiation has ailowed the heat from the <br /> building to prevenl large, long•lasting accumulations of snow on the roof. Consequently, <br /> there was less need for a strong rooi structure. However, nvw that we are increasing the <br /> insulation in these buildings, the rooi structures must support greater accumulations of snow. <br /> Further, the e}fects of overstressing a wooden sfructure are cumulative; it may eventuatly fail <br /> with n0 increase in load. Even if the structure doesn't tail, it will sag. For these reasons, <br /> consideration should be given to increasing the roof strength in any such building. <br /> Structural ventilation is leSs than that which iS provided in normal constructien practice. <br /> i recOmmend that the roof structure and the aflic ventilation be improved so that they meet <br /> modern building standards. <br /> i ,,, , � CHIMNEY; My inspection was limited because I was unable to reach the top of the chimney. <br /> WALIS AND CEILINGS: Walls are among the least inspectable parts of a building, simply <br /> beCause both sides are co��ercd. Unreported deficiencies can exist in any conCealed <br /> struCture. Frequently, cra;-;cing or other damage to walls are indicative of deficiencies i� other <br /> ��,pa e building, r�ther than in the walls themselves.,,l._�nade the_fpllc : . ._:_ �.___ � :�= <br /> """''o"`T� tivalls 3nd`cei`ingsi <br /> The walls show some cracking, but I do not consider it excessive or indicative of any <br /> significant structural deficiencies. <br /> There is water staining and damage to the ceilings in piaces. There is mucii greater <br /> than normai risk oi associated hidden structural damage. <br /> The capacity of the walls ot this building to resict laterai loads, such as those that <br /> occur during an earihquake, is poorer than average. <br /> TUE ANO SHOWER SURROUND: The tub and shower surround in the lower apartment is a <br /> wainscot of Ceramic tiles. We tind that many ceramic tile instaliations do not keep the water <br /> out of the structure over the lor;�� term. It is critical thai their waterproofness b? carefully <br />