My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2817 RUCKER AVE 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
2817
>
2817 RUCKER AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 11:47:28 AM
Creation date
3/8/2017 9:47:27 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2817
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MEANS OF EQRES9 <br /> within Uie builJing which are within 75 feet 5. The dcwr asKmbly shall cumply with the applica- <br /> (22 860 mm)u(thc rcvolving doors. bie fire protwtion rrting anJ,when�r�teJ,shall be <br /> 4. Therc is an acwation of a munuul control ���-��osing or automatic closing by smoke de�ec- <br /> switch,in an appmved la ation and clearly ��on in acconlance witl�Sectiun 715.d.7.3,shall tx <br /> defined,which reduces the holding force to installeci in acconiance with NIYA 8Q :u�d shall <br /> bcluw ttie 130•pound(572)force IeveL ��mply with Section 715. <br /> 6. The duor ussembly shall have un intcgraled <br /> IW8.1.3.2 Power-operaled doo�s. Wherc means of swndby Ewwer supply. <br /> egress doors•rre operated by power,such•rs doors wilh a <br /> photcelecuic-actuated mechanism�o open the door upon 7• '►1�e door assembly power supply shall be eleavi- <br /> the approach of u person, or doors v.�ith puwervassisted cally supervised. <br /> manual operation, the design sha!I b: such that in thc 8. The Jcwr shall opcn to ihe minimum reyuircd <br /> event ot powcr (ailurc, the door is capable uf being wid�i within 10 seconds after uctivruun of the ' <br /> opencd manually to pennit means o(egrcss travel or o�rating dcvice. <br /> closed wherc nccess:uy to safcgu:ud means of egress. 1008.1.3.4 Access•contru0cd egress doors. The <br /> The forces rcquireJ tu upen thcse dairs manuully shall <br /> not exceed those s�cified in Section 1008.I.2, except entrsnce diwrs in a means of egrcss in lwiWings with an <br /> thut the Corce to sct the Joor in mouon shall not cxcecd SO acupancy in Group A,B,E,M,R-I or R-..�nd entrance <br /> pounds(220 N).The dcwr shall bc capablc of swinging doors to lenant spaces in uccupancies in Groups A,8,E, <br /> from any position to �he full width o!the opening in M, R-I and R-2 ane pennfued to � cyuipixd with an <br /> which such duor is inslalled when a force is applicd to�he approved entrance anJ egrcss uccess contmi sys�em <br /> Juor on the side (rom which egrexs is made. WhichshallbeinsWlleclinacconiancewithallofthe(ol- <br /> �ull-power-o�x;rated doors shall cumply with BHMA lowing criteriu: <br /> A156.10. Powervassisted un� low-energy dcwrs shall 1. A sensor shall Ix� pruvided un the egress siJe <br /> comply wilh BHMA A156.19. :urrnged to Jetect an occupxnl approuching �he <br /> Jcwn.7'he d�wrs shall he;urrnged lu unlock by u <br /> ExcepHons: signal Gum or loss of power to Ihe sensor. <br /> t. Occupancies in Group 1-3. 2. Loss of Ewwer ro Ihat pan of the•rccessconunl sys- <br /> 2. Horizon�al sliding doors complying with Sec- tem which lock� lhe diwrs shall autnmalic;illy <br /> uun I(bR.l 33. unlock Ihe dcwrs. <br /> 3. For a biparting dour in the cmergency brc�ilcout 3• 7'he doon shall be:urangcd to unlock Gum a m:m- <br /> mcxle,adattleaf IocaleJ wilhin u multiple-leaf ual unlixking device Icxated JO inches l0 48 <br /> opening shall be czcmpt frum !he minimum inchcs(1016mmtol219mm)verticallyabovethe <br /> 32-inch (813 mm) single-lea(req�ircment of tluor•rnd within 5 feet(1524 mm)of the secured <br /> Sec[ion I IX)8.1.1,provided a minim��m 32•inch dewrs.Rendy access shall be provided lo the man- <br /> (813 mm)cle:v o�x ning is provided when the uul unlocking device and �he device shall be <br /> two bipaning leaves meeting in the center are clearly idcntified by a sign Ihat rcaJs"PUSH TO <br /> brokcn out. EXPI'." When upermed, the manual unla:king <br /> device shall rcsul�in dircct interruption of power <br /> 11NI8.1.3.3 Horizunlal sliding doors. In other than to�helcek—independentoftheaccessconuvlxyx- <br /> GruupHoccupmicies,ho�imntulslidingduonpcmiined tem electronics—rnd the doors shall remain <br /> to be a cumpement o(a means of egrcss in accortiance unlocked for a minimum of 30 seconds. <br /> with Exception 5 to Section I W8.1:?shall comply wiih <br /> all o(the folluwing criteria: 4. Activation of the building firc al:um system, if <br /> provided, shull automatically unlock the doors, <br /> I. The duors shall oe puwer operateef and shall bc and the doors shall remain unlockeJ until�he firc <br /> capable of being opera�ed manually in the cvent of alarm system has been reset. <br /> �wer failurc. 5. Acuvation of the building auwma:,c sprinkler or <br /> 2. The doors shall lxx openable by a simple method fire detection system,if providai,shall automati- <br /> from bodi sides without special knowledge or cally unlock the doors. 7'he doors shall rcmain <br /> ef(on. unlockcd until�he firc al�um sysiem has been icset. <br /> 3. The 1'orce rcquircd to opemte the door shall nut 6. Envance doors in buildings with an ixcupancy in <br /> excccd 30 pounds(133 N)to set ihe door in motion Group A,B,E ur M sh�ll n�t be secured from Uie <br /> and I S pounds(67 N)to close the dcx�ror open it to egrexs side during periods that the building is open <br /> !he minimum rcquired width. to We geneml public. <br /> 4. The duur shall be openable with a force not ro 1008.IJ.5 Secudty grilles. In Groups B, F, M and S, <br /> eaceed IS pounJs (67 N) when a force of 25U horiwntal sliding or vertical securiry grilles aze pecmit- <br /> pounds (I I W N) is applicd perpendiculu to the ted at the main exit and shall be openable from the inside � <br /> dcwr adjxcent to the opernting device. without the use of u key or special knowledge or effort <br /> 2008 INTERNATIONAL BUILDIN6 CODE� � I�I�^ <br />
The URL can be used to link to this page
Your browser does not support the video tag.