3025 RUCKER AVE TRASK SURGICAL CENTER 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
3025
>
TRASK SURGICAL CENTER
>
3025 RUCKER AVE TRASK SURGICAL CENTER 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2019 9:43:49 AM
Creation date
3/8/2017 10:46:36 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3025
Tenant Name
TRASK SURGICAL CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CONFIDENCE TESTING <br /> AUTOMATIC SPRINKLER SYSTEMS <br /> � � <br /> pDDRESS c� � <br /> OCCUPIED AS ^ �� `� <br /> BUILDINGOWNER s /�.1-' PHONE y7.T'3/)'��✓� <br /> ADDRESS CTfY Z� CODR <br /> DATE OF INSPECTION� D TYPE OF INSPECTION: ANNUAL OTEIER <br /> � <br /> TESTER'S NAME(PLEASE PRIlVT)1 b�� �� _SFP CER'fIFICATIbN NOS�oiUl <br /> DRY SYSTEM: <br /> I, ?. Trip test irip conducted:......................................... Yes IYf�o ❑ <br /> � ' Systcm tn'p� seconds. <br /> � <br /> � 2, All flow switches,supervisory switches �o❑ N/A ❑ <br /> ' And alarm bells tested: <br /> .................................................. es <br /> ' Static Pressure: 6 7 psi <br /> ' 3. Alara►bell operates:..................................................... Yes �No❑ N/A❑ <br /> t Yes E!' No� <br /> ; 4. Flowtestsconducted�................................................. <br /> ,f. Flow pressure:�_Psi ,� � <br /> � 2-inch drain7 ..............................................................Yes I�No❑ <br /> � _ ` <br /> ' S. Systems inspected end lubricated: ....................................Yes L�' No ❑ <br /> ' 6. Air compressor refills 3ystem in 30 minutes:..........................Yes I�No� <br /> 7, System drained and restoted to normal operation:....................Yes �1'No❑ <br /> 8. Were the heat actuation devices cested on <br /> ` Pre-action and deluge systems? ........................................Yes ❑ No ❑ N/A� <br /> WET SYSTEM: � � <br /> 1. Flow test conductgd: .......................................................Yes L�No ❑ <br /> E Static pressure: �A sl <br /> Flow pressure: si <br /> 2-inch drain7 Yes I� No ❑ Other ❑ <br /> ............................................................... <br /> 2. Flow switches, supervisory switches �No � N/A ❑ <br /> And alarm bells tested:..................................................Yes <br /> 3. Alarm bell operates: ..................:...:...:............................Yes i��'�I�o ❑ N/A ❑ <br /> 4. Systems inspected and lubricated: .......................................Yes L�No ❑ — / <br /> , ' S. Pressure regulating valves tested:....................................•.••Yes � No ❑ N/A I� <br /> (tumble) <br /> ; �-0 ��Z <br /> i (��9i) <br />