Laserfiche WebLink
, l � Page 2 of 3 <br /> i <br /> Archkectural V1lerks, Inc. tM0107-4d <br /> -----Original Messagr.----- I <br /> From: Tony Lee [mallbo:Tlee�d,everett,wa.usj I <br /> Sent: Wednesday,]uly 11,20013:40 PM � <br /> 70: Mattfiew Gregory <br /> Sub]att: RE: Everett Surgkal Center,3025 Rucker Avenue, Ptan Chedc !1 BOS 06-034 <br /> Matt: <br /> Sorry this is taking so bng, I've actually been looking at it for awhile now and am just about ready to stamp <br /> the plans. The main houbling factor is(and hes always been)the occupanq type. During our meeNng of <br /> May 27�� we discussed the issue and at that Hme the logical condusbn was to allow the B Occupancy <br /> classification to remain. Duing the plan revbw, I talked about this project with the Building Offidal, Tim <br /> Tyler, aa to the dibmma. We both teel that k would be more appropriata to classify the uppertnost fbor as ' <br /> R should have been done the last Nne it was in for pertnit in 1982 -and call it a"Nonconforming, Existing 1- <br /> 7.2." <br /> I have been doing this review under that assumption and have found no changes(yet)that would have to <br /> be made at this Hme based on thia revised classificaHon. <br /> These are the issues that I can find so far— <br /> 1. A 4-hour occupancy separation is required between I and S-3 Occupanciea of Table 3-B, �� <br /> 2. A ramp from the second Noor to grade is required by Section 1007.57(rega�dless of an I <br /> elevator it appears)—I haven't quite figured that one out yet, � <br /> 3. I 1-2 Occupancies of nonsprinklered V 7-Hr construction are limited to the first story per � <br /> Table 5-B, <br /> 4. The building is of mixed construction types—not pertnitted per Section 607.1 and out of <br /> compliance per 601.2 <br /> 5. Corridors are required to be a minimum of 6'clear where serving operaHng areas—there <br /> is an existing column in one corridor currenty. <br /> These issues do not have easy fixes and are the result of previou,decisions—of which we have no record <br /> of. I propose then that we revise Me occupancy classification and allow Me above listed discrepancies ta <br /> take on a nonconfortning status. In the future, if there are revisions to the building that would effect any of <br /> the above discrepancies, we would address them on a case-by-case basis. <br /> Curcently, I would ask that the altemate stair enclosure extension as shown on Detail 1/A2-7 should be <br /> built. <br /> I would also like to discuss the idea of bringing the building rtwre into conformance in the(near)future by <br /> installing fire alarm and sprinkler systems. i <br /> Please send me back any thoughts,or call me at(425)257-8870 to discuss this letter. <br /> Thanks, Tony <br /> i <br /> -----Orfginal Message----- <br /> From: Matthew Gregory[mailto:Matthew@AWerks.cum] <br /> Sent: Wednesciay,]uly 11, 2001 2:29 PM <br /> To: 'tlee@ci.everett.wa.us' <br /> SubJect: RM: Everett Surgiwl Center, 3025 Rucker Avenue, Plan Check # BOl 06-034 �I <br /> See below. Using different email address zince first came back. <br /> -----Origfnal Message----- <br /> From: Matthew Gregory <br /> Sent: Wednesday, ]uly li, 2001 222 PM <br /> 7/12/01 i <br /> i <br /> i <br /> # <br />