My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3408 RUCKER AVE 2016-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
3408
>
3408 RUCKER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/3/2017 6:09:01 PM
Creation date
3/8/2017 11:22:58 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3408
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ PUBLlC SERY/CE5 OEPARTA/ENT <br />Inspection Observations al 3408 Rucker Ave 12/7/09 <br />At the request of the Violations Hearings Examiner an inspection was performed at this location by <br />members of the City o( Everett Buildir.o Division and the City of Everett Planning Division. <br />The purpose of the Inspection was to determine the status of the building (or compliance with the <br />minimum standards per Title 16 and title 19 of the Everett Municipal Code. <br />This buiiding is currently being used as a duplex and is in violation of provisions within Ti[le 16 and 19 of <br />the EMC as the building is approved for single family dwelling occupancy only. To bring the building into <br />compliance with the minimum standards [he (ollowing list has been prepared. <br />1. The installation of a one hour fire rated door must be installed between the two units at the <br />party wall ��liere a non rated door currently exists or the opening can be fremed in and 5/8" <br />type x gypsum wallboard applied to each side of the framed in opening. <br />2. A one hour fire ratecl barrier must be installed beb.aeen the units above and in line with the <br />dividing party wall. This would entail the creation of a iramed wall structure at this point <br />covered with an application of one layer of 5/8" [hick type x gypsum wallboard attached to each <br />side of this framed structure and would extend from the common wall below to the sheathing of <br />the roof above. <br />3. Smoke alarms must be instailed in each bedroom and on each floor level outside of the <br />bedroom areas. These smoke alarms must be "hardwired" ro the buildings electrical system and <br />be provided with a battery backup system. <br />4. Electricai receptacles on the ungrounded system shall be corrected ro comply with the 2008 <br />Edition of the National Electrical Code section 406.3.d. <br />5. The Iaundry washing machine in "unit A" requires tLe installation o( a"P Vap" on the drein line. <br />6. The basement area lacks the required headroom to be used for occupied space. The owner has <br />agreed that this is the intended and current use of this area. <br />7. The Planning department has separate site requirements which must be resolved per attadied <br />letter. <br />8. An additional solution would be to retum the building to single family use only. hi this option no <br />corrections to the building are necessary. <br />9. Pemiits and Inspection approvals are required for these corrections. A limited time frame <br />should be implemented to require the building be brought into compliance. <br />/- - ,` . , <br />Ted eudden <br />Chief Inspector <br />CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 •(425) 257-8800 • Fax (425) 257-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.