,_. <br />Plan Check #: B 51400 <br />Response to City of Everett <br />Sation 601.4 of the UBC defioea a atructunl frame in thit manner; "The structur�J <br />fnme shaU be conaidered to be tt.e columns �nd t6e girders, beams, truaaes aod <br />apandrds having direct connectiona to the columna aod all other members which �re <br />Esaential to t6e atability oi the building r� a whole." <br />T6e only ateel structured portiona of the Gange building are the 2 atain, and t6e <br />elevator hoiat way fnming. Theae are e:terior dembnts applied to the concrcte <br />building frame aod conaist of a totally independent structunl ayatem. <br />Shirway construction in Type II FR buildings, ia rcquired to be per Section 603.4 <br />"constructed of reinforced concrotq iron or ated with treads and riae�s of conctete, <br />iron or sted.^ We propoae that the stairways as deaigned, meet t6is criteria. The <br />columns supporting the stairways, 5:5:1/4" steel tube, �Jao aupport a ateel canopy <br />inteoded sa wather protection. Regardless of whether the columna were <br />fireproofed with a 2 hour protcetion, if they were in danger of loaing their structural <br />' integrity due to heait in the stair are�, the stairs would be unuaabla A continuous <br />interior concrete r�rop would provide Iloor to Ooor �ccess if both stairs were <br />destroyed by heat and flame. <br />The atcel irame in the elevator hoist way supports the elevator rrils, elevator landing <br />and roof of the hoist way. In a fire the elevator would not be in uae. The removal of <br />the entire devator hoist way, landings and roof, does not aRcet the building <br />atructure, or atructural frame. <br />These exterior dements are bounded by public ways or minimum y�rds of 10 ket or <br />greater, and located adjacent to new fire hydrants installed for �se by the P��rking <br />Garage. <br />Plense call to discuss this further if you do not agree. <br />•9. The Standpipe locatiods sho�vn on sheet A40?, r403 and M04 do not meet the <br />requirement to reach,all azeas of the building with 130 feet of hose, Sec. 0-904.5.4, please <br />revise. <br />The standpipe locations have been coordinated by this olTice with Warren Brty of <br />the City of Everett Fire department. On March 18,1996 in a telep6one discussion, <br />we discussed the 130 foot distance problem when the standpipes were located in the <br />corners of the building, as prefemd by Mr. Bxty. He e:pl�ined to ua that since we <br />are providing a Class I standpipe system, the Ice�tions he prekrnM are fine, and we <br />are not bounded by the 130 foot length. Pleasc confer with Mr. Bwty on this iaaua <br />We are happy to relocate the strndpipes if so required, and will locate them as <br />directed. <br />