Plan Check AB-43963 <br />May 2, 1994 <br />Page 2 <br />5. Provide smoke detectors in ezch sleeping room and in the corridor <br />outside sleeping areas per Sectio� 1210. <br />6. Provide ezhaust fans ducted to the exterior for all bathrooms and <br />ldtchens. 50 cfm min. for bathrooms and 8Q cfm min, for ldtchens. <br />7. If framing cavities are exposed, the wall must be insulated �to the <br />thiclmess of the f�aming. If the building is re-roofed the attic must be <br />insulated to R-30 minium. If windows are replaced, they must meet the <br />requirements of the Energy Code. <br />. In order for the processing of your application to condnue, it will be necessary to <br />provide the Building Division with two complete new sets of drawings reflecdng the <br />cornctions requested. <br />Upon resubmital of the drawings, your application will be given priority and plan <br />review will recommence. <br />All required submittals shall be of sufficient deC�il and wntain sufficient informadon to <br />ensure that the proposed swcture will be constructed in compliance with a:l adopted <br />codes. <br />Sincerely, <br />Jeff McFall <br />Associate Enginccr/Building <br />jd/1}.lmrypa/J96J <br />(:ITV (1F F\/FRFTT• 3;00 C�dar Sireet • Everetl, WA 98201 •(206) 259-8800 • Fax (206) 259-8856 <br />