My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3920 RUCKER AVE 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
3920
>
3920 RUCKER AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 3:53:12 PM
Creation date
3/9/2017 12:03:34 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3920
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
87
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plan Check hB-435962 <br />June 6, 1994 <br />Page 2 <br />1/6. Vertical reinforcing bars are required in foundation walls. For <br />conventional foundation walls #4 bars at 24" O.C. are acceptable, <br />retaining walls must be engineered. <br />I1171'v 7 Indicate stud spacing for cripple walls and other walls. <br />✓8. The gjardrail at the deck must be 42 inches high. <br />t/9. Foundation vents are required per sec. 2516(c)6. 12.53 sf of vent area <br />is required. <br />1/110. An 18" by 24"minimum acce-s opening is required to the crawl area. <br />6""11. Smoke detectors are required within each sleeping room and outside each <br />sleeping room. Smoke detectors must have a battery back-up power <br />source in addition to the building wiring power source. <br />WV' ✓12. An accessible parking stall is required and an accessible route of travel <br />r�K� from the stall to the ground floor units is required. <br />/13. Please provide energy calculations or the prescriptive insulation values in <br />table 6-1. <br />In order for the processing of your application to continue, it will be necessary to <br />provide the Building Division with two complete new sets of drawings reflecting the <br />corrections requested. <br />Upon resubmital of the drawings, your application will be given priority and plan <br />review will recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to <br />ensure that the proposed structure will be constructed in compliance with all adopted <br />codes. <br />Sincerel <br />rffr:o <br />fall <br />Associate Engineer <br />jdgM(w4396 <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 259-8800 • Fax ('06) 259-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.