My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4004 RUCKER AVE 2016-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
4004
>
4004 RUCKER AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/5/2017 1:53:13 AM
Creation date
3/9/2017 12:17:51 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4004
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
120
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Js. <br />Minimum 2" z 2" x 3/16" thick piate washers should be providcd for the anchor <br />bolts. Table 23-II-I-1, Exception 3 S'�rr O�K� 1 <br />M <br />3' <br />E�dNog � �� � <br />The egress window for bedmom M2 in the basement unit is not shown on the Nocth <br />Elevation. The lower sill for the window should be no higher tt►an 44" above the <br />finist�ed floor - a window well may be requircd. Section 310.4 C�T4 Ans�3 <br />C�Tt�e stair enclosure should surcound the stairs completely - a portion is missing <br />within the garage at the basement leveL Section 100533.3 �►/o7r /KsaT f�� N <br />� R�ccessibility Stc B��Reow .T�'r*'- /e+�r y <br />�1. The unit in the basement should compiy as a Type B dwelling unit per Section <br />1103.1.8.2. <br />� 2. The main entry door from within the stair enclosure to the Type B unit should be <br />accessible. A minimum of 18" clear should be provided from the edge of the door <br />to any interior wall. Note that the door ro the living room could comply as the main <br />entry door if it were along an accessible route of travel. Sections 1106.10.3, Item 1 <br />and 1106.27.1, Exception 4. <br />v 3. A minimum 30" z 48" maneuvering space should be shown in the bathroom of the <br />Type B unit. Section 1106.27.1, Exception 3 <br />� 4. The lateral distance from the centerline of the water closet to the wall should be 18 <br />inches. The edge of an adaptable lavatory may be located not less than 15 inches <br />from the centerline of the water closet. Section 1106.11.5.1 �'ot�Qqr�nts� e p P�6�'j� <br />� 5. Grab bars (or blocking if adaptable) should be provided for the toilet. Note that this <br />may prohibit the location of the toilet next to the tub. Section 1106.11.5.3 <br />� 6. A clear floor space of 30" deep (perpendicular) by 48" wide (parallel) should be <br />shown adjacent to the tub. Other fixtures should not be located within this space. <br />Section 1106.27.1, Exception 12 <br />� 7. Grab bars complying with Section 1106.11.9.3 should be pmvided for the tub. 1'he <br />location of blocking should be shown on the plans. <br />Please prepare a response letter showing where each item in this correction letter is addressed on <br />the plan set. <br />2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.