My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4305 RUCKER AVE 2018-01-01 MF Import
>
Address Records
>
RUCKER AVE
>
4305
>
4305 RUCKER AVE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/30/2019 9:09:23 AM
Creation date
3/9/2017 1:04:50 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4305
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
146
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JOHN H. FARRENS, <br />8726 202nd STRE[T S.VJ., [DI✓,ONDS, <br />October 1, 1974 <br />JR., • ARCHITECT <br />�^/ASHINGTON 98C20 • t20Gi 774-1965 <br />Mr. Jamie Johnson, Inspection Supervisor <br />Inspection DepartmenC <br />City of Everett, <br />Everett, Idashington <br />Reference: Ben Hong Restaurant <br />4305 Rucker <br />Everett, Washington <br />Type V-N, Occupancy B-3 <br />Fire Zone 3, Occu,ant Load 7_20 <br />Vic.or C. Martin, Architect <br />Dear Jamie: <br />The following items should be submitted or correcCed befare the but:�+�ng <br />permit is issued. <br />1. Ventilation shall comply with Sec. 705. Pfechanical drawings sh�uld <br />be subnitted, riot just a note on Che drawings that they will comply with <br />the requirementa of the Everett Inspection Department. <br />2. The mec}:anical drawings shall show how the building is heated. <br />3. Occupant load signs shall show the number of occupants. The drawings <br />should be corrected to read: "Occupant load 48" in dining and banquet room; <br />'bccupant load 98" in dining room; and "Occupant load 79" in cocktail lovnp,e. <br />4. A conforming exit door shall be located in cach part of the dining and <br />banquc.t room if it can be entirely enclosed by sliding panels. Exit doors <br />shall be a minimum of 3'0" wide and shall be swinging type doors. Secs. <br />3303(b) and 3303(f). <br />5. Structural. calcuiations shall be submitted, including roof, foundation <br />and retaining walls. <br />6. 7iilet rooms shall comply with Sec. 1711(b) and (c). Doors to toilet <br />roomt shall be 32 inches clear. A 2'8" door is not 32" clear. This is <br />especially imporCant where the wheel chair must turn in or adjacent to the <br />opening. The counter for the women's lavatories shall be detailed showing <br />the required opening under one lavatory. A note on the dramings stating <br />that toilet rooms shall comply with the referenced sections is not sufficient. <br />��,1� 7. A pl�ambing riser diagram is required to be suUmitted before the permit <br />� ;v can be issued. <br />
The URL can be used to link to this page
Your browser does not support the video tag.