Laserfiche WebLink
June 21, 1982 <br />Little Castle Restaur� t <br />4322 Rucker Avenue <br />Everett, Washington 98203 <br />Attn: Jack Thompson <br />SUBJECT: E�ECTRICAL�PERMITINOS� 06721and 00992 <br />Dear Mr. Thompson: <br />.P �t�ryl�l�'�'�' <br />GITY OF <br />everett <br />CITY HAIL • ]SYbilS <br />EVERETT, WA61/�NGTON <br />vezo, <br />IN'�ECTION DEP�RTMENT <br />An inspection of the structure at 4322 Rucker was performed by the <br />were revealedrtmThese^deficiencies8arenoutlined1below;deficiencies <br />1. The exhaust fan (range hood) duct through the,roof can <br />not be inspected to show compliance with 2-hour con- <br />struction. A letter is to be submitted stating that <br />the construction meets the 2-hour fire resistive require- <br />ments, also a sketch is to accompany the letter indicating <br />the constr�ction details (to be submitted within 10 days). <br />2, Knockouts in the electrical service panel are to be <br />filled in. <br />3, No disconnect on the unit on the roof. <br />4. Exterior sign in front of the building must have GFCI <br />protect9on. <br />5, The sign must have the GFCI protection. <br />6, The flashing arrow on the sign is not permitted by code <br />and shall either be removed or made non-functional. <br />7. The required solid fence screening of 6 feet has not been <br />erected along the west property line, <br />