My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4509 SEAHURST AVE 2018-01-02 MF Import
>
Address Records
>
SEAHURST AVE
>
4509
>
4509 SEAHURST AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2022 8:57:37 AM
Creation date
3/9/2017 2:10:00 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAHURST AVE
Street Number
4509
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
everett <br />December 27, 1990 Y <br />Randy Payne the l,rggr rn <br />4509 Senhurst Avenue ,nrrn <br />Everett, WA 98203 <br />everell <br />P5: Owner: Randy Payne <br />Job Address 1,509 Senhurst Avenue <br />Plan Check Mo. 90/26082 <br />Dear Mr. Payne: <br />In response to your application for n construction permit, your plans have <br />been examined and you are advised that the issuance of n permit is being <br />withheld for the rensons listed below. <br />✓1. The rxisting lower level. Is not shown In sufficient detail. Show <br />locations and sizes of all doors, windows and the use of all interior <br />spaces including Enrage. <br />/2. Show proposed stairs on lower level floor plan. <br />4. One -hour occupancy separation is required between n group 2, Division 3 <br />(single family dwelling) and M (private gnrnge) occupancy; the <br />separation may be limited to the instnllntlon of materials approved for <br />one -hour resistive construction on the garage side and a self -closing, <br />tightfitting, solid wood door 1-3/8 inches in thickness will be <br />f-, permitted in lieu of a one. -hour fire nsscmbly. <br />v Maintain minimum 618" headroom at stairways. URC 3306(p). <br />Stairways serving one individual dwelling uric in Croup R, Division 1 <br />or 3 may have one handrail. The top of tha h.ndrnil shall be placed <br />not less than 31. inches nor more than 38 L.rheo above the nosing of <br />treads. UBC 3306(J). <br />A landing shall be not more than 7-1/2" below the finished floor level <br />provided the door does not swing over the landing. URC 3304(1). <br />/7. Provide smoke detectors as required by Section 1210 URC. <br />A. Highlight new construction in nome way so —as to easily distinguish <br />between new construction and exiatinr. <br />®. Finish showers to a Leight of 70" above drain inlet with smoo Ur, hard, <br />noncbsorbent surface. UBC 510. <br />
The URL can be used to link to this page
Your browser does not support the video tag.