My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4509 SEAHURST AVE 2018-01-02 MF Import
>
Address Records
>
SEAHURST AVE
>
4509
>
4509 SEAHURST AVE 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2022 8:57:37 AM
Creation date
3/9/2017 2:10:00 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAHURST AVE
Street Number
4509
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r Everett <br />7110L/C WORKS I" <br />ENGINEERING / PUBLIC SERVICES DEPARTMENT 11111 <br />2002 <br />February 22, 2005 <br />Mr. Kevin McKay <br />4509 Seahurst Avenue <br />Everett, WA 98203 <br />RE: Owner: McKay <br />Job Address: 4509 Seahurst <br />Plan Check No: B0502-007 <br />Dear Mr. McKay: <br />In response to your application for a concruction permit, your plans have been examined and <br />you are advised that the issuance of a permit is being withheld for the reasons listed below. <br />These comments address building issues only. Additional revisions, or additions, may be <br />required by other departments (such as Utilities, Planning or Fire). All references refer to the <br />2003 International Building Code, as amended by the State of Washington and/or Washington <br />State Energy Code, 2001 Edition, unless stated otherwise. <br />In order for the processing of your application to continue, it will be necessary to provide <br />the Building Division with two complete new sets of drawings reflecting the corrections <br />requested. <br />1. The plans should indicate the species and grades of all framing members. <br />The plans should indicate the requirement for pressure tre2tment of all framing <br />members. <br />3. The deck is required by code to support a live load of 40 psf in addition to its own <br />dead weight. The allowable bending stress of the 6 x 12's will be exceeded for most <br />grades of lumber under the proposed configuration. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensue <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />Steve Miller 1 <br />Associate Engineer <br />CITY OF EVERETT • 3200 Cedar Street • Everett, V,A 08201 • (425) 257-8200 • Fax (425) 257-8856 <br />DEDV"C"SUMLLER1 502{ 7(450 S"INRSn <br />
The URL can be used to link to this page
Your browser does not support the video tag.