Laserfiche WebLink
Ltr. J. Pikkcrt <br />May S, 2007 <br />Pagc 2 <br />8. Provide 1" cicar air space over baffles. Baffles shall extend 6" vertically above batts <br />and 12" vertically abave loosefill insulation. <br />9. Provide detail of 2 x 8 rafter conncction to Iedger in the storage space on the second <br />floor. <br />10. Providc bearing for 2 x 8 rafters in storage space at thc exterior wall. <br />11. Show how the storage space is ventilated. <br />12. Provide attic ventilalion calculations. Show required ventilation size and location. <br />13. Provide stair section. Show all requirements for stairs, guard, handrail etc. on stair <br />section. <br />14. Provide fire blocking along stringcr and at mid-run of stairs. Show on stair details. <br />15. Provide brick veneer d�tail(s) as needed to show compliance with requirements of <br />Section R703.7. <br />1G. Provide detail of construction where courtyard abuts wood framing. <br />17. Provide smoke alarms per R313. Show all required alanns on plans. <br />18. Provide Gmil black polyethylene film in crawl space. Lap edges 12". <br />Please prepare a response Ietter showing where each item in this correction letter is addressed <br />on thc plan set. <br />Upon resubmittal of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals shall be of sufficient detail and contain sufficient information to ensure <br />that the proposcd strucmre will be constructed in complianr� with all adopted codes. <br />Sincerely, <br />�-wC/ <br />Jeff Iici man <br />Dceclopment Technician <br />❑I:I)I/PLNCAMSIA'111:I1.fIdKlCOIM-Q1511106 SIAIIURST ACI) <br />