PURLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per Gty Standard#601. <br /> 5. Connect side sewer per City Standard#'s 601, 602, 604. <br /> 6. Connect all rooHop downspouls to the side sewer. <br /> 7 Connect roottop�ownspouts to the drainage system provided for this lot. <br /> 8. Rooflop runoH must be discharged to a roof downspout infiltration system per City of Everelt Storm <br /> Manual 3-2.6.2. The approximale size trench is 3.5'wide, 2'deep and 25' long. See atlachment for <br /> more details. <br /> � The contractor must mee[with the Pi iblic Works Inspector�o discuss potential drafnage rouling prior to <br /> beginning the pro;ect Call Randv Allen at 425-339-7403 I/Call CIiH Lindman at 425-339-7404. <br /> 10. Install erosion controi measures as determined by the Public Works inspector, such as silt tence, straw <br /> ba�es, swales, or erosion blankets. <br /> 11. Install erosion control measures per City oi Everett Standards for small parcels <br /> 12. Remove erosion coNrol measures upon comoletion of the project prior to final approval of the permit <br /> 13. All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permided site. No wasting of malerial is allowed on this buitding bt. <br /> 14 No dirt, mud, rocks or debris to be tracked onto roadway. <br /> 15. No t,uilding materials lo be slacked on sidewalk/roadway and sidewalk/roadway to be kept clean and <br /> open for pedestrian travel. <br /> 16. Adjust water meter box 1"above sidewalk grade. <br /> 17. Remove and repiace curb, gutter and sidewalk as per City of Everett Standard Plan#'s 305A& 306 on <br /> this proposal's fronlage as direcled by the Public Works Inspector(i.e. all unused driveways and any <br /> brohen or damaged area must be replaced). <br /> 18. Install a Type I concrete driveway per Cily of Everett Slandard #307 <br /> 19. Pave driveway from lhe iront property Iine out lo the street paving. <br /> 20. Pave to existing paving in alley. <br /> 21. Conlacl the Water District for connecling provisions for this building's water and <br /> sewer services. <br /> 22. A catch basin as per City Standard Plan #402 with a gas trap per Slandard Plan #410 is required for the <br /> parking area. <br /> 23. If a sewer pump system is to be installed, the pressure line must discharge into a private mannole, then <br /> gravity flow across the public right-of-way. <br /> 24. A sprinkler system is required for this building in compliance with the requirements of NFPA Standards <br /> 13D. <br /> 9�- S�DE �e,2 �� N� uP��3�nN4 T�cr� � Pkb�o�v �v� , <br /> PWCommeMslRevaM61B711 . � � <br />