My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3430 SEVENICH DR 2018-01-02 MF Import
>
Address Records
>
SEVENICH DR
>
3430
>
3430 SEVENICH DR 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/22/2022 1:47:00 PM
Creation date
3/9/2017 5:45:31 AM
Metadata
Fields
Template:
Address Document
Street Name
SEVENICH DR
Street Number
3430
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P!/BL/C N/O/ZKS , <br /> � <br /> �����, <br /> Apri129, 1993 <br /> W. D. Rucker <br /> 20115 44th Avenue \'Jest <br /> Lynnwood, Washington 98036 <br /> RE: Owner: W. D. Rucker <br /> Job Address: <br /> Plan Check No.: 399�3 <br /> Dear Mr. Rucker: <br /> In response to your application for a construction permit, your plans have been <br /> examined and you aze advisul that the issuance of a permit is being withheld for the <br /> reasons listed below. These comnients address building issues only, additional <br /> revisions or addi[ions may be required by olher departments (such as Utilities, Planning <br /> or Fire). All references refer to the 1991 Uniform Building Code, as amended by the <br /> State of Washington and/or Washington State Energy Code 1991, 2nd Edition, unless <br /> stated otherwise. <br /> • ' <br /> C I. Plans do not show locations of whole het�se fan and source specific fans. <br /> Show size and location of all re:quired fans on the plans. <br /> 2. Provide calculations to show sizing of whole house fan maintain minimum <br /> 0.35, maximum 0.5 air changes per hour. <br /> 3. Provide smoke detectors in all sleeping rooms and in the corcidor or area <br /> giving access to each separate sleeping area. Detectors shall be installed on <br /> each story and in the basement. <br /> 4. Provide window schedule for all windows. Show tested u-value of all <br /> windows. <br /> 5. Winding stairs may be used if the required width of run (9" min) is provided <br /> at a point not more than l2" from the side of the stairway where the treads are <br /> the narrower, but in no case shall any width of nm be less than 6 inches at any <br /> �int. (Stairs at entry) <br /> 6. Provide cross section at stairs. Show all construction and show all required <br /> dimensions, ie.. treact, riscr, handrail size, handrail height. <br /> CITY OF EVERETT• 3200 Cedar Strcet • Everett, VJA 9P.201 • (206) 259-8800 • Fax (206) 259-8656 <br />
The URL can be used to link to this page
Your browser does not support the video tag.