My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10529 WASHINGTON WAY 2016-01-01 MF Import
>
Address Records
>
WASHINGTON WAY
>
10529
>
10529 WASHINGTON WAY 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2017 7:58:36 AM
Creation date
3/9/2017 7:58:29 AM
Metadata
Fields
Template:
Address Document
Street Name
WASHINGTON WAY
Street Number
10529
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
il , .•� • � <br /> �. <br /> II7. Section R409.1 requimd that a minimum of 75% of permanently installed lamps in <br />,' lighting fixtures shall be high- efficacy lamps. <br /> 8. Construct�on documents shall include details regarding insulation and their R- values; <br /> fenestration U-factors; mechanical system design criteria, mechanical and service water <br /> heating system and equipment types, sizes and efficiencies; equipment and system <br /> controls; duct sealing, duct and pioe insulation and location; and air sealing details. Pe� <br /> Section R103.2 U✓A State tnergy Code (WSEC). <br /> 9. Handrail ends shall be returned or shall terminate in newel posts or safery terminals. <br /> 10. Please clarify reference :o"Girder Floor" on second floor freming plan. <br /> 11. Provide post or multiple studs at point loads (rom beams girders and trusses. <br /> 12. Noh S on sheet A-5 references "the following shear wall schedule", with no scredule <br /> provided. Please correct. <br /> 13. Show how roof above overhead garage door is supported. <br /> 14. Show height calculations on at least one elevation view. <br /> i Please prepare a response lelter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will bc given priority and plan review will <br /> recommence. <br />�I All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will b� constructed in compliance with all adopted codes. <br /> Sincerely� <br /> /f�I`�'� I <br /> � �,;';`' � :� . <br /> /� <br /> )ef1 Heihnan <br /> Development Technician <br /> 425-1_57-8976 <br /> Email: jheilmanCalci.everettwa,us <br /> , 5.AICominonAClriiray�HCi'.manAC1�107�017(10179Wa5�inqlonClay)dW. ���� <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.