Laserfiche WebLink
. - � � t <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> 5. Connecl side sewer per City Standard#'s 601, 602, 604. <br /> � Connect all rooHop downspouls lo the side sewer. <br /> 7. Connecl rooflop downspouts to lhe drainage system provided for this lot. <br /> 8. Rooftop runoffi musl be discharQed to a roof downspout infillration syslem per City of Everett Slorm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25' long. See attachment for <br /> more d�tails. <br /> I 9.. The contraclor musl meet with lhe Pubiic�Vorks Inspector lo discuss potential drainage routing prior lo <br /> `� beginning the project. <br /> 10.� Install erosion conlrol measures a�delermined by the Public Works inspector, such as sill fence, slraw <br /> bales,swales,or erosion blankets. <br /> 11. Inslall erosion control measures per Cily of Everett Slandards tor small parcels <br /> �� <br /> / 12.� Remove erosion control measures upon completioii o(the project prior to final approval of Ihe permit. <br /> �/ <br /> 13. All excavated material(rom(ounUa(ion, sidewalk and driveways shell be hauled to an approved, <br /> permilfed site. No wasting of material is allowed on this building lot. <br /> _� <br /> 14. No dirt, mud, rocks or debris lo be tracked onto roadway. <br /> 15. No buiiding malerials to be stacked on sidewalks and sidewalks lo be kept clean and open tor <br /> pedestrian travel. <br /> 16. Adjusl water meter box 1"above sidewalk grade. <br /> 17. � Remove and replace curb, guUer and sidewalk as per Ciry of Everett Standard Plan#'s 305A 8 306 on <br /> this proposal's frontage as directed by lhe Public Works Inspeclor(i,e. all unused driveways and any <br /> broken or damaged area musl be replaced). <br /> 18. Install a Type I co�crele driveway per Cily of Everet� Standard #307. <br /> 19. Pave dri��ew.y trom lhe fronl properly line oul to Ihe slreet paving. <br /> 20. Contact the Waler Districl for connecting provisions tor this building's water and <br /> sewer services. <br /> 21. A calch basin as per Cily Standard Plan H402 with a gas trap per Standard Plan#410 is required for lhe <br /> parking area. <br /> 22. If a sewer pump system is lo be installed, the pressure line musl discharge into a private manhole,then <br /> graviry flow across lhe pubiic right-of-way. <br /> 23. A sprinkler system is required for this building in comp�iance with the iequirements of NFDA Slandards <br /> 13D. <br /> 1 <br /> P�'JCommenls , '�+ . I <br />