PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connecl side sewer per City Standard#601. <br /> 5. Connect side sewer per Cily Standard#'s 601, 602,604. <br /> 6. Connect all rooflop downspouls to the side sewer. <br /> 7. Connect rooftop downspouls to the drainage system provided for this lot. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everelt Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide,2'deep and 25' long. See attachment for <br /> more details. <br /> 9. The conlraclor must meet wilh tha Public Works Inspector lo discuss polential drainage routing prior to <br /> beginning the project. <br /> 10. Install erosion control measures as determined by lhe Public Works inspeclor, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 11. Inslall erosion coNrol measures per City of Ev�refl Slandards for small parcels <br /> 12. Remove erosion control measures upon completion of ihe project prior to final approval of the permit. <br /> 13. All excavated malerial from foundalion, sidewalk and driveways sha�l be hauled to an approved, <br /> permilted sile. No wasting of material is allowed on this building lot. <br /> 14. No dirt, mud, rocl:s or debris lo be tracked onto roadway. <br /> 15. No building materials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian travel. <br /> 1G. Adjust waler meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, c�utler and sidewalk as per Ciry of Everetl Standard Plan #'s 305A 8 306 on <br /> this proposal's(rontage as direcled by lhe Public Works Inspector(i.e. all unused driveways and any <br /> broken or damaged area musl be replaced). <br /> 18. Install a Type I concrele driveway per City of Everelt Standard#307. <br /> i)Ll:Y <br /> �1� Pave driveway from the front properiy line out to the skeel paving. <br /> 20. Contact the Water Dislricl for connecling provisions for this building's water and <br /> sew�er services. <br /> 21. A catch basin as per City Slandard Plan #402 with a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is lo be inslalled, the pressure line must discharge into a private manhole,then <br /> graviry(low across lhe public right-oi-way. <br /> 23. A sprinkler syslem is required for this building in compliance wilh lhe requirements of NFDA Standards <br /> 13D. <br /> Pl9f,ommen�s <br /> yZ <br />