Laserfiche WebLink
NWTE NorthWest Tower Engineering <br /> WSDOT Monopole, Everett, WA Report No. 140636.05 September 16, 2014 <br /> 120 1' HP MW Dishes (Clearwire) 1/2" # 47 <br /> 120 3' HP MW Dish (Clearwire) '/2" # 48 6 <br /> 125 16' Platform w/Handrail N/A N/A µ; <br /> ii <br /> 128 (1) 10' x 2.5" Omni antenna (1) 15/8" # 19 <br /> 150 3ft Lightning Rod N/A N/A ,_ <br /> aF&T'9Ai"MVITAMAMIAMPICAnAfil:ra.SC M,+MMMY/4D...fltWWWC.'S MALRV.`i#LG4O e r4r.1fb M'.'d fRalit'.MFFi NTI ktaRte RCIFW WWWITA.42E,WI4'EMIZINWNANA.FAIM 'MYd:RYII A u'P,17tFi0 <br /> * Equipment assumed to be installed per NWTE structural analysis report no. 120636.04 dated <br /> 05-16-12. <br /> Existing & Proposed Appurtenances <br /> All existing antennas and the following: <br /> Nx RKrs.t.,i' .Ji 24,J..N-"vai #1g, W Vk,.:skw„3t W4.11 ,7,F'fritTeV.kF 4,,Mlf:.ARF4 S, - .c>._, ..«<ia E......'31 :,WS M,Ai:FF:,nx.A ':5VEMR.Rr'A )6tC,Pi,N W W,,,,, E-%: <br /> a Elevation (ft) Appurtenance Tx Line Tx Line No. 0 <br /> Remove <br /> (3) Kathrein 742-265 Panels Remove <br /> il (2) Powerwave P65-17-XLH-RR Panels (6) 7/8" #13 - 18 I <br /> (1) KMW AM-X-CD-16-65-00T-RET Panel (6) '/8" #60 - 65 <br /> tir (12) TMA's <br /> 94 Proposed Proposed <br /> (3) Commscope SBNHH-1065C Panel (2) Power Cable #72,73 <br /> (3) ALU AA 3JR52703AAAA Panel (1) Fiber Line #74 <br /> (6) WCS RRH Units w/ Pipes <br /> (1) Raycap Surge Suppressor <br /> AT&T <br /> 411RM:.c'SGA^il'kCVERSEEMZOIM:%➢Bifid4".Ni'g'RINFRWS`PllSl"N$!xM•MkP".M WIT,;S"4•@RCNIE'8,44E"dS/Y'e`MONBA':S"u'dt5`5Cw&5G+n'ELI r):e'To A+414RGSs5MT7.'9V'tm"R5Fgfae lffw`iiMTVVV.:W:way+"4.u'+'.31R.Y4.IRMteNL'.IR'fl^,' 9,,,,it <br /> Antenna center elevations are listed for microwave, yagi, and panel type antennas. Base <br /> elevations are listed for other antenna types. <br /> Existing and proposed AT&T antenna and feed line information was provided by WesTower and <br /> Ryka Consulting in construction drawings by B+T Group dated 05-28-14. Tower geometry, <br /> member size, and appurtenance information was gathered during NWTE's site visits. <br /> The monopole steel yield strengths are unknown and are assumed as follows: <br /> ➢ Monopole Shaft 65 ksi <br /> ➢ Baseplate 50 ksi <br /> ➢ Anchor Rods 75 ksi <br /> ➢ All Other Members 36 ksi <br /> The attached drawings show monopole geometry, structural member sizes, existing and <br /> proposed antennas, feed lines, and other supported appurtenances. <br /> NorthWest Tower Engineering www.nwtower.net <br /> 2210 I Iewitt Ave,Suite 209,Everett,WA 98201-3767 i Tel 425-258-4248 Fax 425-258-4289 <br />