Laserfiche WebLink
IaU.J it <br /> DESIGNED APPURTENANCE LOADING <br /> TYPE ELEVATION TYPE ELEVATION <br /> Generic Lightning Rod 3'copper 151 (2)LPA-80080/8CF(Verizon) 110 <br /> 10'x2.5"Omni Mast 128 (2)Swedcom 9014-DN Panel(Dead) 99 <br /> N W O O <br /> Platform At 125-ft 125 (2)Swedcom 9014-DN Panel(Dead) 99 <br /> - 22 v m o N n Platform At 125-ft 125 (2)Swedcom 9014-DN Panel(Dead) 99 <br /> -„`5., a w N 22 <br /> e Platform At 125-ft 125 T-Fame Mounts(Dead) 99 <br /> v 111111111 Kathrein 84010054 Panel(clearwire) 117 T-Fame Mounts(Dead) 99 <br /> 11111 Kathrein 84010054 Panel(clearwire) 117 T-Fame Mounts(Dead) 99 <br /> Kathrein 84010054 Panel(clearwire) 117 (2)Kathrien 742265 Panel(ATI) 94 <br /> 0 i Dragonwave 1ft MW(clearwire) 117 (2)Kathrien 742265 Panel(ATI) 94 <br /> I. .11111. GPS(clearwire) 117 (2)TMA(ATI) 94 <br /> / I �I II'., 1111111, <br /> I2 I 1 Kathrein 84010054 Panel(clearwire) 117 (2)TMA(ATI) 94 <br /> 107.1 ftu Kathrein 84010054 Panel(clearwire) 117 AWS RRH Unit(ATI) 94 <br /> Kathrein 84010054 Panel(clearwire) 117 AWS RRH Unit(ATI) 94 <br /> 3'MW HP(Clearwire) 117 AWS RRH Unit(AT) 94 <br /> �!I' i l 1 ,I 1 Pipe Mount(clearwire) 115 Raycap Squid Surge Protector(ATI) 94 <br /> IC I 111'1 Pipe Mount(clearwire) 115 (2)TMA(ATI) 94 <br /> to iv _ Pipe Mount(clearwire) 115 (2)WCS RRH Unit(ATI) 94 <br /> n <br /> Q. <br /> m o q I l l Huawei RRU3702(dearwire) 115 Pipe Mount(ATI) 94 <br /> a NI `v' to 0 4 o Huawei RRU3702(dearwire) 115 (2)WCS RRH Unit(ATI) 94 <br /> `r m Huawei RRU3702(clearwire) 115 Pipe Mount(ATI) 94 <br /> Huawei RRU3702(dearwire) 115 (2)WCS RRH Unit(ATI) 94 <br /> Huawei RRU3702(clearwire) 115 Pipe Mount(All) 94 <br /> InIF O Pipe Mount(dearwire) 115 Commscope SBNHH-1065C(ATI) 94 <br /> / Pipe Mount(dearwire) 115 Commscope SBNHH-1065C(ATI) 94 <br /> 69.0 ft Huawei RRU3702(dearwire) 115 Commscope SBNHH-1065C(ATI) 94 <br /> Pipe Mount(dearwire) 115 ALU AA 3JR52703AAAA(ATI) <br /> ALU AA 3JR52703AAAA(ATI) <br /> 94 <br /> (2)LPA-80080/8CF(Verizon) 110 94 <br /> (2)LPA-80080/8CF(Verizon) 110 <br /> ALUM 3JR52703AAAA(ATI) 94 <br /> Antal BXA-70063/8CF(Verizon) 110 Raycap Squid Surge Protector(ATI) 94 <br /> ffi Antel BXA-70063/BCF(Verizon) 110 (2)Kathrien 742265 Panel(ATI) 94 <br /> g `�i S 6 Antel BXA-70063/BCF(Verizon) 110 Platform At 90-ft(ATI) 90 <br /> v223 m ALL REACTIONS Antel BXA-185085-12CF(Verizon) 110 Platform At 90-ft(All) 90 <br /> ARE FACTORED Antel BXA-185085-12CF(Verizon) 110 Platform At 90-ft(ATI) 90 <br /> Antel BXA-185085-12CF(Verizon) 110 GPS and Mount 62 <br /> 1 Platform At 110-ft(Verizon) 110 Platform At 40-ft 40 <br /> 1111113111111AXIAL Platform At 110-ft(Ve zon) 110 Platform At 40-ft 40 <br /> 64040 lb <br /> 34.0 fl II' Platform At 110-ft(Verizon) 110 Platform At 40-ft 40 <br /> SHEAR MOMENT MATERIAL STRENGTH <br /> 2447 lb 215268 lb-ft <br /> GRADE Fy Fu i GRADE I Fy 1 Fu <br /> mn TORQUE 110 lb-ft A572-65 65 ksi 80 ksi <br /> 5 ai 5 rn - 30 mph WIND 0.2500 in ICE <br /> o N N AXIAL TOWER DESIGN NOTES <br /> 52543 lb 1. Tower is located in Snohomish County,Washington. <br /> 2. Tower designed for Exposure B to the TIA-222-G Standard. <br /> SHEAR MOMENT 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. • <br /> 28656 lb 2501240 lb-ft 4. Tower is also designed for a 30 mph basic wind with 0.25 in ice.Ice is considered to increase in thickness with height. <br /> 5. Deflections are based upon a 60 mph wind. <br /> o.o ft 6. Tower Structure Class III. <br /> o TORQUE 869 lb-ft 7. Topographic Category 1 with Crest Height of 0' <br /> § REACTIONS-85 mph WIND 8. TOWER RATING:43.3% <br /> o <br /> a_ s t <br /> to o c <br /> `o a m 5 a <br /> J = <br /> b <br /> s {f <br /> t5 c E ,cS 0- Lii R W <br /> 61 J Z g to H m 6 t' <br /> (// I;) <br /> Northwest Tower Engineerin °I1140636.05 150'MP, WSDOT Monople,Everett, WA-: <br /> 2210 Hewitt Ave. Suite 209Project:Proposed 85-mph(3-sec Gust),30-mph with 1/4"Ice <br /> NWTF Everett,WA 98201 client:WDrawnestower/Ryka/AT&T Drawn by:Kirk Wiebe APP'd: <br /> R,. ..,..e6 <br /> NwrE Phone:(425)258-4248 code: TIA-222-G Date:09/17/14Scale: NTS <br /> CA V•,,nc\,co Anon Path: Dwa No.c 4 <br />