Laserfiche WebLink
� ( � <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> 5. Connect side sewer per City Slandard#'s 601,602, 604. <br /> 6. Connect all rooftop downspouts to the side sewer. <br /> 7. Connect rooftop downspouts to the drainage system provided(or this lot. <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25'long. See attachment for <br /> more details. <br /> � The conlractor must meet wilh lhe Public Works Inspector to discuss potential drainage rouling prior to <br /> beginning the projecl. <br /> 10. Inslall erosion conlrol measures as determined by lhe Public Works inspector, such as silt fence, straw <br /> bales,swales,or erosion blankets. <br /> 11. Install erosion control measures per City of Everett Standards for small parcels <br /> 12. Remove erosion control measures upon completion of the project prior to final approval of the permit. <br /> 13. All excavated material from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permilled site. No wasting of material is allowed on this building lol. <br /> 14 No dirt, mud,rocks or debris to be ti acked onto roadway. <br /> 15. No building malerials to be stacked on sidewalks and sidewalks to be kept clean and open for <br /> pedestrian travel. <br /> 16. Adjusl waler meter box 1"above sidewalk grade. <br /> � Remove and replace curb, gutter and sidewalk as per City of Everett Standard Pian#'s 305A&306 on <br /> this proposal's frontage as directed by the Public Works Inspector(i.e.all unused driveways and any <br /> broken or damaged area musl be replaced). <br /> 18. Install a Type I concrete driveway per Cily of Everelt Standard#307. <br /> 19. Pave driveway from lhe tront property line out to the street paving. <br /> 20. Contact the Water District for connecting provisions for this building's water and <br /> sewer services. <br /> 21. A catch basin as per City Slandard Plan#402 with a gas trap per Standard Plan#410 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be inslalled, the pressure line must discharge into a private manhole,then <br /> gravity flow across the public right-of-way. <br /> 23. A sprinkler system is required for this building in compliance with the requirements of NFDA Standards <br /> 13D. <br /> PWCanmenis /� (/1/ <br /> \ � <br />