My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2512 WETMORE AVE 2016-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
2512
>
2512 WETMORE AVE 2016-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/9/2017 11:53:17 AM
Creation date
3/9/2017 11:53:06 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2512
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � � . � ; <br /> Ltr.J.Fullwiler(B0204-020) <br /> April 19, 2002 <br /> Page 2 <br /> ( d.J Exhaust ducts should not pass through the occupancy separation, as <br /> v smoke/fire dampers would be requirod. The ezhaust cuns should be <br /> shown. Section 713.10&713.11 <br /> ` /Z. A detail and listing should be provided for all one-hour walls separating <br /> V individual dwelling units. Section 310.2.2 <br /> ( 3.J There is appioximately 3 feet of floodceiling assembly that separa[e�, dwelling <br /> l/ units. A listing for the one-hour conswction should be shown or. the plans. <br /> Secdon 310.2.2 <br /> � Walls separating dwelling units from each other and the carpotts should be shown <br /> as having minimum 50 STC's. I_isting sho�ld be provided. Adopted Appendix <br /> Section 1208.2 <br /> 1 `. A'he floor/ceiling assembly portion that separtes dwelling unils should be shown <br /> ��as having a minimum STC of 50 and a minimum I[C' �f 50. Adopted Appendiz <br /> 5ecuons 1208.2 Rc 12U83 <br /> � 6. ,Altic drafr stops should be shuwn in line o��er the dweiling unit sepazati�n walls. <br /> �� Phe construction should be nutedon the plans. Section 708.3.1.1.2 <br /> It should be verified that the 4-0 single-hung bedroom winduws will provide 24" <br /> minimum clear openable height(provide a cut sheet). Section 310.4 <br /> The great room, dining and kitchen areas do not meet the minimum natural lighr <br /> requirement of 1/10 the floor area as prescribed in Section 1203.2 <br /> Q e locations of the water heaters should be shown. The tanks should be shown <br /> with approved straps to the saucture at the top and hottom 1/3 of the tank. i1MC <br /> Section 308.1 <br /> 10. e dryer moisture ezhaust ducts will exceed a length of 14'. Listed high output <br /> dryers should be installed. Section 504.3.2, UMC <br /> Constructlon <br /> �. The north and south exterior walls must tx a minimum of 5 feet from the propeRy <br /> lines in order to comply w�ih exterior wall and opening requitsments. Secqons <br /> 310.4& 503.2.1 <br /> O <br />
The URL can be used to link to this page
Your browser does not support the video tag.