My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2802 WETMORE AVE GOLDS GYM 2018-01-02 MF Import
>
Address Records
>
WETMORE AVE
>
2802
>
GOLDS GYM
>
2802 WETMORE AVE GOLDS GYM 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2022 7:30:00 AM
Creation date
3/9/2017 1:10:36 PM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2802
Tenant Name
GOLDS GYM
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
June 1, 1994 <br />Mr. Don Berg <br />Port Gardner Partners <br />2731 Wetmore Ave., Suite 500 <br />Everett, WA 98201 <br />RE: Owner: Port Gardner Partners/Golds Gym <br />Job Address: 2802 <br />02 Colby Avenue <br />Plan Check q <br />Dear Don: <br />In response to your application for a construction permit, your plans have been <br />examined and you are advised that the issuance of a permit is being withheld for the <br />reasons listed below. These comments address building issues only, additional <br />revisions or additions may be required by other departments (such as Utilities, Planning <br />or Fire). All references refer to the 1994 Uniform Building Code, as amended by the <br />State of Washington and/or Washington State Energy Code. 1994, 1st Edition, unless <br />stated otherwise. <br />rl 111. All buildings and additions or alterations over 4,000 square feet of <br />construction area require the plans and specifications to be prepared by <br />an architect currently licensed to practice in the State of Washington, <br />RCW 18.08 <br />2. Walls and ceilings of corridors are required to be of 1-HR fire -resistive <br />construction. Section 3305(g). An architectural section through the <br />corridor is necessary to determine how this is accomplished. <br />3. Interior openings into corridors are required to be protected as set forth <br />in Section 3305(h). Self -closing or automatic closing twenty -minute <br />rated door assemblies properly gasketed should be provided. Other <br />openings are limited to 3/4-HR rated fixed glazing and shall not exceed <br />25 % of the area of the common wall. The corridor must be closed at the <br />end adjacent to office 104. <br />1/4. Elevators must be separated from exit corridors by elevator lobbies or <br />doors. Lobbies must be of one -hour fire -resistive construction with 20 <br />minute rated doors and 45 minute rated openings per Section 3305(h). <br />Doors closing against elevator openings must be 20 minute rated with a <br />4" x 24" window and panic hardware mounted on the elevator side of <br />the door. Section 33050). <br />CITY OF EVERETT• 3200 Cedar Street • Everett, WA 98201 • (206) 259-8800 • Fax (206) 259-8856 <br />
The URL can be used to link to this page
Your browser does not support the video tag.